Skip to main content
NetApp Knowledge Base

BIOS upgrade error: Failed to save Primary Image to Backup flash device

Views:
3,490
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:
4/22/2025, 2:41:20 AM

Applies to

  • AFF A300
  • AFF A320
  • AFF A200
  • AFF A220
  • AFF A700s
  • FAS 8200
  • BIOS update
    • Manual
    • ANDU

Issue

New BIOS version: 11.15
New LOADER version: 6.0.14
Enabling write access to the flash ME region...
ME region - write access enabled.
Saving Primary Image to Backup flash device
fail unlocking memory
Failed. -4 bytes written: I/O error
Failed to save Primary Image to Backup flash device. Programming of Primary aborted
Automatic firmware update skipped (update_flash command failed).

Warning: The boot media contains a newer firmware image (11.15).
Please run 'update_flash' at the Loader prompt to update your
system firmware (11.11).

New BIOS version: 11.15
New LOADER version: 6.0.14
Enabling write access to the flash ME region...
ME region - write access enabled.
Saving Primary Image to Backup flash device
-------------------------------------------------------
---------.+**** Flash verify failed. ****
Failed. -4 bytes written: I/O error
Failed to save Primary Image to Backup flash device.  Programming of Primary aborted
*** command status = I/O error(-4)

  • If performing an Automated Non-Disruptive Upgrade (ANDU), the upgrade is  paused because the partner is not in a "waiting for giveback

::> cluster image show-update-progress 
                                             Estimated         Elapsed
Update Phase         Status                   Duration        Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks    completed                00:10:00        00:00:35
Data ONTAP updates   paused-on-error          01:23:00        00:37:18
 
Details:
 
Node name            Status            Status Description
-------------------- ----------------- --------------------------------------
node-01         waiting
node-02         failed            Error: Node "node-02" is not in
                                       "waiting for giveback" state.
                                       Action: Use the "storage failover
                                       show" to verify that node
                                       "node-02" is in one of the
                                       following states: "waiting for
                                       giveback" or "connected".

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.