All drive in shelf reporting shelf serial number instead of Shelf ID after shelf chassis replacment
Applies to
- FAS8300
- ONTAP 9
- DS460C
Issue
- The below message is seen from the events logs after the shelf chassis replacement.
Fri Jun 23 13:40:21 -0400 [node2: dsa_worker4: ds.sas.id.conflict.detected:error]: SAS shelf on channel 0d (shelf ID: 0, S/N: 021803001631) reported a shelf ID conflict.
Fri Jun 23 13:40:41 -0400 [node2: dsa_worker2: ds.sas.id.conflict.cleared:notice]: Shelf ID conflict on channel 0d (shelf ID: 0, S/N: 021803001631) was cleared.
- From sysconfig -a logs:
021803001631.0: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH71HUG)
021803001631.2: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH6M43G)
021803001631.4: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH312KG)
021803001631.6: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH6SLHG)
021803001631.8: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH72R3G)
021803001631.55: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH6JM8G)
021803001631.57: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH71J1G)
021803001631.59: NETAPP X376_WVELE08TA07 NA00 7486.1GB 520B/sect (VGH61T3G)
Shelf 0: DS460-12 Firmware rev. IOM12 A: 0270 IOM12 B: 0270
- Physically verify the Shelf ID displayed on the shelf. Confirm shelf ID is set to 00 and is reporting green LED.