CONTAP-244031: SwitchFanNotPresent_Alert reported after ONTAP upgrade to 9.13.1
Issue
- These Ethernet switch health monitor alerts occur after upgrading to 9.13.1:
hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-4
hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-3
hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-2
hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-1 - When checking switch status directly, no errors are reported.
- The issue has only been reported on Cisco Nexus 3132Q-V (NX3132) switches.
- You can check fan health with the "show environment fan detail" command on the Cisco Nexus switch.
- Example:
Switch> enable
Switch# show environment fan detail
Fan:
---------------------------------------------------------------------------
Fan Model Hw Direction Status
---------------------------------------------------------------------------
Fan1(sys_fan1) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan2(sys_fan2) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan3(sys_fan3) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan4(sys_fan4) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan_in_PS1 N2200-PAC-400W -- front-to-back Ok
Fan_in_PS2 N2200-PAC-400W -- front-to-back Ok
Fan Zone Speed: Zone 1: 0x3.2