Issue

  • These Ethernet switch health monitor alerts occur after upgrading to 9.13.1:
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-4
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-3
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-2
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-1
  • When checking switch status directly, no errors are reported.
  • The issue has only been reported on Cisco Nexus 3132Q-V (NX3132) switches.
  • You can check fan health with the "show environment fan detail" command on the Cisco Nexus switch.
  • Example:
    Switch> enable
    Switch# show environment fan detail
    Fan:
    ---------------------------------------------------------------------------
    Fan Model Hw Direction Status
    ---------------------------------------------------------------------------
    Fan1(sys_fan1) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan2(sys_fan2) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan3(sys_fan3) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan4(sys_fan4) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan_in_PS1 N2200-PAC-400W -- front-to-back Ok
    Fan_in_PS2 N2200-PAC-400W -- front-to-back Ok
    Fan Zone Speed: Zone 1: 0x3.2

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.