Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 2583 results
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-Issues/CONTAP-272629
      Issue The REST API call is invoked from SCV application and the issue is causing snapvault update to fail from SCV.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-Issues/CHW-3166
      Issue No LEDs in the management module No console output The issue remains after the module re-seat
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC-Issues/CSNAPC-8301
      Issue When using Hourly scheduling, with more than one hour between backups, the backups shift by one hour visibly when DST comes and goes. However, on change away from DST< you may see two backups wi...Issue When using Hourly scheduling, with more than one hour between backups, the backups shift by one hour visibly when DST comes and goes. However, on change away from DST< you may see two backups with almost identical time stamps due to anything scheduled from 2:00 to 2:59 running twice, since that time period is actually run through twice in real time.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-Issues/CONTAP-289899
      Issue Event log reporting OFW transfer timed out on one Node: Mon Jul 22 13:00:00 +0200 [netapp-01: svc_queue_thread: cf.ic.xferTimedOut:error]: HA interconnect: OFW transfer timed out. Mon Jul 22 13:...Issue Event log reporting OFW transfer timed out on one Node: Mon Jul 22 13:00:00 +0200 [netapp-01: svc_queue_thread: cf.ic.xferTimedOut:error]: HA interconnect: OFW transfer timed out. Mon Jul 22 13:00:00 +0200 [netapp-01: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'prevstate': 'SF_UP', 'newstate': 'SF_UNKNOWN', 'progresscounter': '0'} No issues on HA ports visible
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/NW_Issues/CONTAP-108482
      Issue Ports on the X91153A NIC installed in AFF A900 systems intermittently flap when using optical cables to connect to Cisco Nexus 9336C-FX2 switches as Cluster Interconnect switches.
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/NW_Issues/CONTAP-432346
      Issue During boot, the following messages are seen: e1e: Disabled multicast promiscuous mode e1a: Disabled multicast promiscuous mode e4e: Disabled multicast promiscuous mode e4a: Disabled multicast p...Issue During boot, the following messages are seen: e1e: Disabled multicast promiscuous mode e1a: Disabled multicast promiscuous mode e4e: Disabled multicast promiscuous mode e4a: Disabled multicast promiscuous mode e8e: Disabled multicast promiscuous mode e8a: Disabled multicast promiscuous mode
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/RAID_Issues/CONTAP-416215
      Tue Dec 17 2024 03:43:53 GMT [NETAPP-FLASH-02: storlog_admin: sla.shelf.message: DEBUG] params: {'type': 'SEVERITY', 'log': 'Tue Dec 17 03:42:44 2024 ( 0+00:00:53.210); 02000093; U?; HAL; hal; 04; Mod...Tue Dec 17 2024 03:43:53 GMT [NETAPP-FLASH-02: storlog_admin: sla.shelf.message: DEBUG] params: {'type': 'SEVERITY', 'log': 'Tue Dec 17 03:42:44 2024 ( 0+00:00:53.210); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 4-Watchdog reset (regVal:0xC4)'} Tue Dec 17 2024 03:55:55 GMT [NETAPP-FLASH-02: storlog_admin: sla.shelf.message: DEBUG] params: {'type': 'SEVERITY', 'log': 'Tue Dec 17 03:54:39 2024 ( 0+00:00:53.244); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 4-Watchdog reset…
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-Issues/CHW-2960
      Issue FAS system experiences a controller disruption after an NVMe command timeout on a Flash Cache device.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-Issues/CHW-1015
      Issue Message example: [netapp01-01: send_boot_msg_thread: mgr.stack.saved:notice]: Reboot with saved panic information in log file [netapp01-01: send_boot_msg_thread: mgr.stack.string:notice]: Panic ...Issue Message example: [netapp01-01: send_boot_msg_thread: mgr.stack.saved:notice]: Reboot with saved panic information in log file [netapp01-01: send_boot_msg_thread: mgr.stack.string:notice]: Panic string: Uncorrectable Machine Check Error at CPU8.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-Issues/CHW-2871
      Issue ONTAP cluster node reboots unexpectedly: page fault (supervisor write data, page not present) on VA 0x10 cs:rip 0x20:0xffffffff806e08d6 rflags 0x10046 in process idle: cpu15 on release 9.11.1P9 ...Issue ONTAP cluster node reboots unexpectedly: page fault (supervisor write data, page not present) on VA 0x10 cs:rip 0x20:0xffffffff806e08d6 rflags 0x10046 in process idle: cpu15 on release 9.11.1P9 (C)
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/FS_Issues/CONTAP-352298
      Issue ONTAP cluster node reboots unexpectedly: process on cpu13 hung (wafl_exempt14) for 5002 milliseconds! in SK process wafl_exempt18 on release 9.15.1P4 (C)