E-Series Persistent cache backup device has failed - AutoSupport Message
Applies to
NetApp E-SeriesEvent Summary
Persistent cache backup device has failed
is reported in the events log on SANtricityCACHE BACKUP DEVICE - Failed
error message is showing in the Recovery Guru.- Additionally, a
CACHE_BACKUP_DEVICE_INSUFFICIENT_CAPACITY
recovery guru failure entry may be logged.
- Additionally, a
- The mSATA drive, used for flushing cache in the events of power down or sudden loss of power has failed.
- Depending on the system configuration, there will possibly be an alert indicating the cache is disabled or suspended. This is to be expected if the cache backup device fails.
Failure Entry 2: WB_CACHING_FORCIBLY_DISABLED-Recovery Failure Type Code: 378"
- Depending on the system configuration, there will possibly be an alert indicating the cache is disabled or suspended. This is to be expected if the cache backup device fails.
Validate
Storage Array Profile shows cache backup device is failed.
Example
Cache Backup Device
Status: Failed
Type: SATA flash drive
Location: Controller B, Connector SATA 2
Capacity: 8,192 MB
Product ID: SV9MST6D030GLM22
Part number: Not Available
Serial number: SPG19020KXS
Revision level: FW11
Manufacturer: XceedLi
Date of manufacture: Not available