E-Series Power supply failed - AutoSupport Message
Applies to
NetApp E-Series
Event Summary
- An AutoSupport messages is generated with title:
E-Series Notification (Power supply failed) CRITICAL
- An associated case is generated with symptom:
EVOLEN:E-Series Notification from Unnamed (Power supply failed) CRITICAL
Validate
- Login to SANtricity Storage Manager or SANtricity System Manager
- Confirm SANtricity reports one of more of the following error messages in the Recovery GURU:
Failure Entry 1: SUPPORT_CRU_NOINPUT-Recovery Failure Type Code: 97
Storage array: xyz
Component reporting problem: Power supply canister (Right)
Status: No power input
Location: Controller/Drive shelf 99
- Confirm from the Hardware tab that the power supply shows as failed
-
Example:
Power Supplies Detected: 2
Power supply status: Optimal
Location: Left
Part number: 114-00148+D0
Serial number: 111111111111111
Vendor: DELTA
Date of manufacture: Not Available
Power supply status: Failed
Location: Right
Part number: 114-00148+D0
Serial number: 222222222222222
Vendor: DELTA
Date of manufacture: Not Available
-
Resolution
- Ensure there are no issues with the power source feeding the PSU (power supply unit).
- Contact NetApp Technical Support as this will likely require a power supply replacement
- If AutoSupport is enabled, this event should have already created a technical support case