SAS ADAPTER INITIALIZATION FAILED - Autosupport Message
Applies to
- ONTAP 9
- callhome.sas.init.failed
Event Summary
- This message occurs when the SAS adapter fails to initialize the link.
Validate
Call home event
HA Group Notification from Node Name (SAS ADAPTER INITIALIZATION FAILED, Port: ) ERROR
EMS Log
- Run
::>event log show -severity * -message-name callhome*
Mon May 02 20:22:33 +0000 [Node Name: pmcsas_asyncd_0: callhome.sas.init.failed:error]: Callhome for SAS ADAPTER INITIALIZATION FAILED, Port
Command Line
Run::>system node run -node <node name> -command sysconfig
slot 1: SAS Host Adapter 1a (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>)
MFG Part Number: NetApp, Inc. 110-00401 rev. B0
Part number: 111-02026+B0
Serial number: 031730000203
Date Code: 20170724
Firmware rev: 03.07.04.00
Base WWN: 5:00a098:007d19f:e0
Phy State: [12] Disabled
[13] Disabled
[14] Disabled
[15] Disabled
Resolution
- Confirm that the SAS adapter is enabled.
- Check the health of the SAS cables.
- If issue persists, please contact NetApp Technical Support and reference this article for further assistance. The solution might require a part replacement.
Additional Information
SAS ADAPTER INITIALIZATION FAILED alert reported in EMS logs