MetroCluster cluster monitoring failed in OnCommand Unified Manager with error: "Unexpected HTTP response code received for storage-bridge-get-iter"

Views:
112
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
om
Last Updated:

Applies to

  • ActiveIQ Unified Manager (AIQUM) 9.x
  • MetroCluster
  • ONTAP 9.x

Issue

  • The following error is displayed in AIQUM WebUI:

Monitoring failed for cluster <cluster_name>. Reason: An internal error has occurred during MetroCluster component fresh.

  • Ocumserver.log will have the following entry:

2020-04-09 00:19:00,028 ERROR [oncommand] [reconcile-1] [<clustre_name>] [c.n.dfm.collector.OcieJmsListener] Error during MetroCluster component monitoring : MetroCluster component monitoring failed. Zapi execution failed Unexpected HTTP response code received for storage-bridge-get-iter from <cluster_name>: 502

  • Zapi-outbound.log will have the following entry: 

20-04-09 00:13:59,353 DEBUG [collection-completion-0] Executing ZAPI request storage-bridge-get-iter to <cluster_name>:

[TRUNCATED]

2020-04-09 00:18:59,375 DEBUG [collection-completion-0] Received ZAPI response for storage-bridge-get-iter from <cluster_name>:

[TRUNCATED]

<results reason="The proxy server timed out waiting for the ontapi server at address <cluster_interface_ip_or_loopback_interface>" status="failed" errno="13114"/></netapp>

Note: What are the notable log files and their respective locations 

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support