Skip to main content
NetApp Knowledge Base

MetroCluster cluster monitoring failed in OnCommand Unified Manager with error: "Unexpected HTTP response code received for storage-bridge-get-iter"

Views:
286
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
om
Last Updated:

Applies to

  • ActiveIQ Unified Manager (AIQUM) 9.x
  • MetroCluster
  • ONTAP 9.x

Issue

  • The following error is displayed in AIQUM WebUI:

Monitoring failed for cluster <cluster_name>. Reason: An internal error has occurred during MetroCluster component fresh.

  • Ocumserver.log will have the following entry:

2020-04-09 00:19:00,028 ERROR [oncommand] [reconcile-1] [<clustre_name>] [c.n.dfm.collector.OcieJmsListener] Error during MetroCluster component monitoring : MetroCluster component monitoring failed. Zapi execution failed Unexpected HTTP response code received for storage-bridge-get-iter from <cluster_name>: 502

  • Zapi-outbound.log will have the following entry: 

20-04-09 00:13:59,353 DEBUG [collection-completion-0] Executing ZAPI request storage-bridge-get-iter to <cluster_name>:

[TRUNCATED]

2020-04-09 00:18:59,375 DEBUG [collection-completion-0] Received ZAPI response for storage-bridge-get-iter from <cluster_name>:

[TRUNCATED]

<results reason="The proxy server timed out waiting for the ontapi server at address <cluster_interface_ip_or_loopback_interface>" status="failed" errno="13114"/></netapp>