Skip to main content
NetApp Knowledge Base

SHM set multi disk failed in Fabric MetroCluster

Views:
94
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
MetroCluster
Last Updated:

Applies to

  • Fabric-attached MetroCluster
  • ONTAP 9
  • Back-end Brocade Switches

Issue

  • There are many fci_device_quiesce, fci_device_timeout and SCSI access errors in EMS, which are set as failed by SHM when the threshold is exceeded.

01Mar2022 19:57:11 fci_device_quiesce adapterName="2c" deviceType="Disk" deviceName="SW_A1:9.126 (0x03050900)" lun="67" cdb="0x9a:0000000051764000:0001:0128" retryCount="0"
01Mar2022 19:57:13 fci_device_timeout adapterName="2c" deviceType="Disk" deviceName="SW_A1:9.126 (0x03050900)" lun="67" cdb="0x2a:6fc80068:0008" retryCount="0"
01Mar2022 19:57:13 scsi_cmd_abortedByHost deviceType="Disk" deviceName="SW_A1:9.126L67" ha_status="0x4" cdb="0x9a:0000000051763f18:0001:00e8" disk_information=""
01Mar2022 19:57:13 scsi_cmd_retrySuccess deviceType="Disk" deviceName="SW_A2:9.126L67" retryCount="1" freeRetryCount="0" cdb="0x2a:6fc80068:0008" dTime="10001"
01Mar2022 20:47:15 shm_threshold_consecutiveTimeouts diskName="SW_A2:9.126L67" count="11"
01Mar2022 20:47:15 scsi_debug debug_string="shm_setup_for_failure disk SW_A2:9.126L67 (S/N xxxxxxxx) error 4000h"
01Mar2022 20:47:15 raid_config_filesystem_disk_failed disk_info="Disk /aggr0/plex6/rg0/SW_A2:9.126L67 Shelf 10 Bay 14 [NETAPP X371_S1643960ATE NA53] S/N [XXXXXXXX] failure_reason="disk driver urgently recommended failing the disk" carrier="" site="Remote"

  • Check SAN Switch supportshow, will found some port connect ATTO that encountered sfp power issue.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.