Issue

Identification

Use the following methods to help identify this issue.

EMS Event Logs

[node1: env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.

[NODE1:monitor.chassisPower.degraded:warning]: Chassis power is degraded: RTC Battery is in WARN LOW state current voltage is 2774 mV, normal low is 2800 mV
 

[env_mgr: monitor.rtcHighPower:error]: Real-time clock battery voltage is above normal (P3.3V Batt is warning high (3307 mV).)

[node1: env_mgr: monitor.rtcWarnLowPower:error]: Real-time clock battery voltage is below normal (2880 mV).

Sensors State
  • The 3 volt battery sensor will show in an alert state:

cluster1::> system node environment sensors show -state !normal

Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
Bat 3.0V                 critlow         2545 mV     2545 mV     2702 mV     3503 mV     3575 mV

or:

P3V Batt                 warnlow         2880 mV     2720 mV     2880 mV     3300 mV     3460 mV 

cluster1::> system controller service-event show

Node             ID  Event Location                      Event Description
---------------- --- ----------------------------------  ----------------------
cluster1-01      1   Controller B on Chassis 1           P3V3_BATT: Voltage Sensor 26 UNC

  • The BMC CLI system sensors and events all commands or the corresponding SP-LATEST-IPMI and SP-LATEST-SYSLOG AutoSupport sections will also indicate the issue:

BMC> system sensors filter BAT

Sensor Name      | Current    | Unit       | Status     | LCR       | LNC       | UNC       | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
P3V_BATT         | 2.840      | Volts      | nc         | 2.720     | 2.880     | 3.300     | 3.460

BMC> events all

Record 904: Wed Mar 18 02:14:02.350000 2020 [IPMI.notice]: 0001 | 02 | EVT: 0157bdbd | P3V3_BATT | Assertion Event, "Upper Non-critical going high" | Reading: 3.307 | Threshold: 3.307
 

Or

Record 1946: Sun May 29 23:44:14 2022 [IPMI.notice]: 6501 | 02 | EVT: 0150bdbd | Bat_3.0V | Assertion Event, "Lower Non-critical going low"

 

Controller Attention LED
  • The amber warning  attention LED on the controller will illuminate

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.