Issue

  • Hardware controller upgrade using manual aggregate relocation (ARL) procedure:
  • After the first node has been successfully upgraded, during aggregate relocation to new node hardware in preparation for the second node upgrade, Flash pool aggregate goes offline and command fails:

Cluster1::*> storage aggregate relocation start -node Cluster1-02 -destination Cluster1-01 -aggregate-list node2_FP_aggr1 -ndo-controller-upgrade true

Cluster1::*> storage aggregate relocation show

Source         Aggregate  Destination   Relocation Status
-------------- ---------- -----------   -----------------
Cluster1-01
               -          -             Not attempted yet
Cluster1-02
               n2_FP_aggr1 Cluster1-01  Failed: Destination node did not online the aggregate on time.

  • The RAID groups containing the SSD Flash Pool disks go missing from sysconfig -r output.
    • BEFORE

Aggregate n2_FP_aggr1 (online, raid_dp, hybrid) (block checksums)
  Plex /n2_FP_aggr1/plex0 (online, normal, active, pool0)
    RAID group /n2_FP_aggr1/plex0/rg0 (normal, block checksums)

      RAID Disk    Device        HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------        ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.10.0       0a    10  0   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      parity      0a.10.1       0a    10  1   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.2       0a    10  2   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.3       0a    10  3   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.10      0a    10  10  SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.11      0a    10  11  SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 

    RAID group /n2_FP_aggr1/plex0/rg1 (normal, block checksums)  << Flash Pool RAID group

      RAID Disk    Device        HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------        ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.10.14P3    0a    10  14  SA:A   0   SSD   N/A 47619/97525248    47627/97541632 
      parity      0a.10.12P3    0a    10  12  SA:A   0   SSD   N/A 47619/97525248    47627/97541632 
      data        0a.10.13P3    0a    10  13  SA:A   0   SSD   N/A 47619/97525248    47627/97541632 

    RAID group /n2_FP_aggr1/plex0/rg2 (normal, block checksums)  << Flash Pool RAID group

      RAID Disk    Device        HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------        ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.10.14P4    0a    10  14  SA:A   0   SSD   N/A 47619/97525248    47627/97541632 
      parity      0a.10.12P4    0a    10  12  SA:A   0   SSD   N/A 47619/97525248    47627/97541632 
      data        0a.10.13P4    0a    10  13  SA:A   0   SSD   N/A 47619/97525248    47627/97541632 

  • AFTER

Aggregate n2_FP_aggr1 (failed, raid_dp, partial, hybrid_enabled) (block checksums)
  Plex /n2_FP_aggr1/plex0 (offline, failed, inactive)
    RAID group /n2_FP_aggr1/plex0/rg0 (normal, block checksums)

      RAID Disk Device          HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------          ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.10.0       0a    10  0   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      parity      0a.10.1       0a    10  1   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.2       0a    10  2   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.3       0a    10  3   SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.10      0a    10  10  SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
      data        0a.10.11      0a    10  11  SA:A   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
    Plex is missing 2 RAID groups.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.