Incorrect speed on management interfaces
- Views:
- 190
- Visibility:
- Public
- Votes:
- 0
- Category:
- element-software
- Specialty:
- solidfire
- Last Updated:
- 4/28/2022, 2:40:13 PM
Applies to
- NetApp Element software
- NetApp SF-series
- NetApp H-series
- Management interfaces (eth2 or eth3)
Issue
- Switch reporting incorrect speed setting (lower than 1Gbs)
%EC-5-CANNOT_BUNDLE2: Gi3/0/8 is not compatible with Gi3/0/9 and will be suspended (speed of Gi3/0/8 is 100M, Gi3/0/9 is 1000M)
%EC-5-CANNOT_BUNDLE2: Gi3/0/11 is not compatible with Gi3/0/12 and will be suspended (speed of Gi3/0/11 is 10M, Gi3/0/12 is 1000M)
- From storage node:
# ethtool eth2
Settings for eth2:
<omitted>
Speed: Unknown (expected: 1000Mb/s)
Duplex: Unknown (expected: Full)
<omitted>
- No alerts in NetApp SolidFire Active IQ (limited fault detection on management interfaces)