Search
- Filter results by:
- View attachments
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/SolidFire_network_ports_show_up_with_incorrect_current_statusApplies to SolidFire Issue When performing network checks with querying the network.json files, sometimes the network ports status show up as incorrect to the current state of the port, for example po...Applies to SolidFire Issue When performing network checks with querying the network.json files, sometimes the network ports status show up as incorrect to the current state of the port, for example port ethX shows as "Up" and not "UpAndRunning," as shown in the node UI (https://nodeMIP:442) An alert can be raised in AIQ for "Detected network configuration mismatch on Bond1G/Bond10G" with "status" : "Up", + "status" : "UpAndRunning" information
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_reboot_an_Element_storage_nodeThis article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This s...This article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This should be done only when needed and under the direction of NetApp Support.
- https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/Uncorrectable_memory_errors_on_SF_Series_storage_nodesApplies to NetApp SolidFire SF-Series Issue On NetApp SolidFire Active IQ: Uncorrectable ECC error detected On iDRAC alert logs: CPU state: IERR Node offline and IPMI log detects: Uncorrectable ECC (U...Applies to NetApp SolidFire SF-Series Issue On NetApp SolidFire Active IQ: Uncorrectable ECC error detected On iDRAC alert logs: CPU state: IERR Node offline and IPMI log detects: Uncorrectable ECC (UnCorrectable ECC | DIMMB1, DIMMB2)
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__Correctable_ECC_memory_error_count_crossed_threshold_on_Memory_controllerApplies to NetApp Element software 12.0 and above NetApp SolidFire SF-Series node NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Error code: memoryEccThreshold Details: Correctable ECC mem...Applies to NetApp Element software 12.0 and above NetApp SolidFire SF-Series node NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Error code: memoryEccThreshold Details: Correctable ECC memory error count crossed threshold on Memory controller: MemCtlr<#> SNMP alert: ECC RAM error: <#> Memory Error Memory Parity Error(<CPU_bank>) - Asserted BMC system event list (SEL): Memory <#> | Parity | Asserted or Memory <#> | Correctable ECC | Asserted
- https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/eth0_and_eth1_are_down_at_the_same_time_repeatedlykern.log reports link down messages for eth0 and eth1 almost simultaneously repeatedly. 2023-01-15T14:23:41.119352Z node1 kernel: [38987319.312240] bnx2x 0000:01:00.0 eth0: NIC Link is Down 2023-01-15...kern.log reports link down messages for eth0 and eth1 almost simultaneously repeatedly. 2023-01-15T14:23:41.119352Z node1 kernel: [38987319.312240] bnx2x 0000:01:00.0 eth0: NIC Link is Down 2023-01-15T14:23:41.299348Z node1 kernel: [38987319.492236] bnx2x 0000:01:00.1 eth1: NIC Link is Down 2023-01-15T15:03:05.904124Z node1 kernel: [38989684.097012] bnx2x 0000:01:00.0 eth0: NIC Link is Down 2023-01-15T15:03:06.004116Z node1 kernel: [38989684.197004] bnx2x 0000:01:00.1 eth1: NIC Link is Down
- https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/How_to_collect_TSR_Technical_Support_Report_logs_from_iDRACApplies to NetApp SolidFire SF-series nodes Description This KB describes the procedure of collecting TSR logs for SolidFire node crash / reboot RCA
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Unsupported_drive_detected_alert_occurs_after_drive_failureApplies to NetApp Element software Issue On NetApp SolidFire Active IQ after drive failure: Error Code: hardwareConfigMismatch Details: Unsupported drive detected in slot x; drive statistics and healt...Applies to NetApp Element software Issue On NetApp SolidFire Active IQ after drive failure: Error Code: hardwareConfigMismatch Details: Unsupported drive detected in slot x; drive statistics and health information will be unavailable. The error does not occur before the drive failure The Element software is the supported version in NetApp Element software micro patch information
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Thermal_trip_followed_by_voltage_outside_of_range_alerts_on_iDRACApplies to NetApp Element software NetApp SF-Series storage nodes integrated Dell Remote Access Controller (iDRAC) Issue Node is no longer responding Errors on iDRAC CPU <#> has a thermal trip (over-t...Applies to NetApp Element software NetApp SF-Series storage nodes integrated Dell Remote Access Controller (iDRAC) Issue Node is no longer responding Errors on iDRAC CPU <#> has a thermal trip (over-temperature) event The system board fail-safe voltage is outside of range The system board 3.3v PG voltage is outside of range The system board VCCIO PG voltage is out of range The system board NDC PG voltage is out of range Error in NetApp SolidFire Active IQ nodeOffline
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_perform_power_drain_on_an_Element_storage_nodeHow to power drain NetApp Element storage node.
- https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/IPMI_unresponsive_and_nodeOffline_repeatedly_after_the_periodic_BMC_cold_resetBeginning BMC cold reset and setting new reset date master-1[30228]: [Event] 30325 GlobalPool-0 serviceshared/EventReporter.cpp:582:ReportEvent|Successfully reported event={id=569216 type=PlatformHard...Beginning BMC cold reset and setting new reset date master-1[30228]: [Event] 30325 GlobalPool-0 serviceshared/EventReporter.cpp:582:ReportEvent|Successfully reported event={id=569216 type=PlatformHardwareEvent nodeID=6 serviceID=107 message=[Beginning BMC cold reset and setting new reset date] details={"bmcResetDate":"2021-09-02T12:49:41","bmcResetDurationMinutes":20160} reported=2021-08-19T12:49:41.644056Z published=2021-08-19T12:49:41.644104Z} mNumEventsPublished=21
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_remove_a_storage_node_from_Element_clusterApplies to NetApp Element software Description This article describes how to remove a storage node from a cluster