Skip to main content
NetApp Knowledge Base

What impact can wafliron have on data availability

Views:
550
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
CORE
Last Updated:

Applies to

  • ONTAP 9

Answer

In the first phase of Wafliron, it will unmount the aggregate and associated volumes and remount them once several baseline checks are completed.

Wafliron's first phase:

  • Restricts client access to volumes.
  • Could temporarily cause an unresponsive console. 
  • May take up to 30-60 minutes to complete.
  • Completion allows serving data while Wafliron continues to check the remaining data.

Note: The time the storage system will spend in the first phase is difficult to estimate due to the number of contributing factors on the aggregate and volumes. These factors include: 

  • Number of Snapshot copies
  • Number of files
  • Size of the aggregate/volumes
  • RAID group size
  • Physical data layout
  • Ongoing RAID reconstructions
  • Number of LUNs in the root of the volume  

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.