Is the takeover possible if the partner has higher ONTAP versions?
- Views:
- 287
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems
- Specialty:
- core
- Last Updated:
- 1/9/2024, 3:01:31 PM
Applies to
- ONTAP 9
- Storage failover
Answer
- If the version of software running on each node of the SFO pair is incompatible, the automatic takeover will not occur when node panics.
- Manual takeover can be allowed if specify allow-version-mismatch while running the
storage failover takeover
command.
::> set advanced
::*> storage failover takeover -ofnode cluster-01 -bypass-optimization true -option allow-version-mismatch
- However, the takeover operation will not be allowed if the partner has higher WAFL or RAID label versions.