- https://kb.netapp.com/Legacy/Brocade_Legacy/SNMP_protocol_version_1_2C_detectedApplies to ONTAP 9 Simple Network Management Protocol (SNMP) Issue Scanner flags EOL/Obsolete Software: SNMP Protocol Version 1/2c Detected.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/The_interface_group_is_in_a_degraded_state_with_flapping_member_portsThe interface group is in a degraded state. [Node1: intr: net.ifgrp.lacp.link.active:error]: ifgrp a0a, port e0f has transitioned to an active state. [Node1: vifmgr: vifmgr.port.monitor.passed:notice]...The interface group is in a degraded state. [Node1: intr: net.ifgrp.lacp.link.active:error]: ifgrp a0a, port e0f has transitioned to an active state. [Node1: vifmgr: vifmgr.port.monitor.passed:notice]: The "link_flapping" health check for port a0a (node Node1) has passed. [Node1: vifmgr: vifmgr.port.monitor.failed:error]: The "link_flapping" health check for port a0a (node Node1) has failed. The port is operating in a degraded state.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Troubleshooting_Workflow__MHost_RDB_apps_out_of_quorumAdditionally, one site might be designated as holding 'epsilon' - an extra partial vote that allows quorum to form with only half the sites. 'Epsilon' is not the same as 'master'. In the two-node HA m...Additionally, one site might be designated as holding 'epsilon' - an extra partial vote that allows quorum to form with only half the sites. 'Epsilon' is not the same as 'master'. In the two-node HA mode, _sitelist contains the HA_CONFIG attribute; this implies that completely different rules are in effect for quorum handling. The typical technique is to cat the /var/rdb/_sitelist, then use the rdb_dump tool to investigate by directing it at the IP addresses of interest (or at localhost).
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/fp_est_scan_start_failed_error_is_reported_on_a_RW_volumeApplies to ONTAP 9 All-Flash FAS (AFF) Temperature Sensitive Storage Efficiency (TSSE) Event Messaging System (EMS) Issue Following error is observed repeatedly in the EMS log: Tue Oct 08 14:32:12 +08...Applies to ONTAP 9 All-Flash FAS (AFF) Temperature Sensitive Storage Efficiency (TSSE) Event Messaging System (EMS) Issue Following error is observed repeatedly in the EMS log: Tue Oct 08 14:32:12 +0800 [CLUSTER-01:scan_tsse_wkr: fp.est.scan.start.failed:error]: Volume footprint estimator scan fails to start on "VOL1" - CDE disabled
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Disks_cannot_be_used_due_to_they_are_part_of_a_stale_aggregateApplies to ONTAP 9 Issue When trying to create an aggregate, the disks that are part of the stale aggregate cannot be choosen to create the new aggregate. The stale aggregate appears in sysconfig -r o...Applies to ONTAP 9 Issue When trying to create an aggregate, the disks that are part of the stale aggregate cannot be choosen to create the new aggregate. The stale aggregate appears in sysconfig -r output. The output of storage aggregate show does not display the stale aggregate. It is not possible to use, delete, or modify the stale aggregate.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Mirror_Replication_Lag_Error_due_to_offline_volume_in_SVMApplies to ONTAP 9 SVM-DR Issue AIQUM reports Mirror Replication Lag Error Risk - Mirror Replication Lag Error Impact Area - Protection Severity - Error State - New Source - AAAAA:->BBBBB: Cluster Nam...Applies to ONTAP 9 SVM-DR Issue AIQUM reports Mirror Replication Lag Error Risk - Mirror Replication Lag Error Impact Area - Protection Severity - Error State - New Source - AAAAA:->BBBBB: Cluster Name - xxxxxxxx Cluster FQDN - XXX.XXX.XXX.XXX Trigger Condition - Mirror Replication Lag Duration exceeds Lag Error Threshold of 12 minutes 30 seconds since Tue, Jan 9 2024 at 05:28:29 CST. Description - Snapmirror One volume is offline in this SVM-DR.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Will_takeover_effect_volume_moveApplies to ONTAP 9 Answer If a takeover occurs before the cutover, the volume move will be failed and destination volume will be deleted also. Need to redo the volume move. If takeover occurs, the vol...Applies to ONTAP 9 Answer If a takeover occurs before the cutover, the volume move will be failed and destination volume will be deleted also. Need to redo the volume move. If takeover occurs, the volume move already in cutover phrase, the volume move can be restarted by trigger cutover after node back to normal. Additional Information additionalInformation_text
- https://kb.netapp.com/Legacy/ONTAP/7Mode/AutoSupport_message__Exceeded_maximum_raw_capacity_CRITICAL[filer11: raid.disk.tooBig.all.reminder:error]: System raw capacity XXX TB exceeds the XXX TB maximum. Reverting to a Data ONTAP release with a lower maximum capacity causes a panic. When reverting to...[filer11: raid.disk.tooBig.all.reminder:error]: System raw capacity XXX TB exceeds the XXX TB maximum. Reverting to a Data ONTAP release with a lower maximum capacity causes a panic. When reverting to a Data ONTAP release with a lower maximum capacity than the capacity supported by the newer version of Data ONTAP, without removing the added capacity, the filer may panic. Reverting to a Data ONTAP release with a lower maximum capacity.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Re-enabling_node_eligibility_during_remove_node_procedure_generates_warningsApplies to ONTAP 9 Node removal procedure Issue During the node removal procedure, a node may be declared ineligible, then have eligibility re-enabled This process may generate warning messages associ...Applies to ONTAP 9 Node removal procedure Issue During the node removal procedure, a node may be declared ineligible, then have eligibility re-enabled This process may generate warning messages associated with cluster quorum
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Volume_move_fails_due_to_object_store_attached_to_aggregate_is_unavailableApplies to ONTAP 9 FabricPool Volume move Issue Attempting to move a volume fails with the error below Volume "vol1" in Vserver "svm1" cannot be moved to aggregate "aggr1" because at least one object ...Applies to ONTAP 9 FabricPool Volume move Issue Attempting to move a volume fails with the error below Volume "vol1" in Vserver "svm1" cannot be moved to aggregate "aggr1" because at least one object store attached to the aggregate is unavailable
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Do_files_and_directories_located_in_a_snapshot_affect_maxdirsize_calculationsApplies to ONTAP 9 Cloud Volumes ONTAP Data ONTAP 8 Directory Answer No, files and directories located in snapshots does not account towards maxdirsize. Additional Information ONTAP file and directory...Applies to ONTAP 9 Cloud Volumes ONTAP Data ONTAP 8 Directory Answer No, files and directories located in snapshots does not account towards maxdirsize. Additional Information ONTAP file and directory structure Resolution Guide