storage pool in degraded status after disk replace and re-seat
Applies to
- Hybrid aggregates
- Storage Pool
- Aggregates with more SSDs cache RAID groups disks than the Storage Pool configuration
- No degraded SSDs cache RAID groups
Issue
- A drive in the storage pool was failed, replaced and or re-seated after a failure.
Storage pool has more number of disks than expectederror reported after that event.::> storage pool showoutput example:
GIJNETAPP::> storage pool show -instance
Storage Pool Name: storage_pool_name
UUID of Storage Pool: 0000a0bc-000a-00a0-abc0-00a0000000bc
Nodes Sharing the Storage Pool: node_name2,node_name1
Number of Disks in Storage Pool: 3
Allocation Unit Size: 279.2GB
Allocation Unit Data Size for RAID4: 186.2GB
Allocation Unit Data Size for RAID-DP: 93.08GB
Allocation Unit Data Size for RAID-TEC: -
Storage Type: SSD
Storage Pool Usable Size: 0B
Storage Pool Total Size: 1.09TB
Is Pool Healthy?: false
State of the Storage Pool: degraded
Reason for Storage Pool Being Unhealthy: Storage pool has more number of disks than expected.
Job ID of the Currently Running Operation: