The cluster triggers the following alert: One node does not respond to NODE CLI commands and the High Availability (HA) is degraded for a manual takeover process. Example at the end of the outputs: ZS...The cluster triggers the following alert: One node does not respond to NODE CLI commands and the High Availability (HA) is degraded for a manual takeover process. Example at the end of the outputs: ZSM - failed, status code = 572, extra = kSMF alternate path failed to host 127.0.0.1 with a kSMF ERROR: RPC: Port mapper failure - RPC: Timed out, max 110s [127.0.0.1:951]. All disk shelfs report that they are not connected to both controllers of the HA pair but the data is being served properly.
Applies to ONTAP 9 Cloud Volumes ONTAP Azure Data Aggregate Disks HA Page Blobs Issue The following EMS message may be seen: Mon Sep 25 01:15:12 +0000 [cluster1-02: OscHighPriThreadPool: pha.obj.throt...Applies to ONTAP 9 Cloud Volumes ONTAP Azure Data Aggregate Disks HA Page Blobs Issue The following EMS message may be seen: Mon Sep 25 01:15:12 +0000 [cluster1-02: OscHighPriThreadPool: pha.obj.throttle:debug]: PHA Obj throttled 956 times on the blob aba22323523 in the container blobcontainer due to the "AZURE_SERVER_BUSY" The following event seen in the Health Events section of Azure portal:
Applies to Cloud Manager Cloud Volumes ONTAP (CVO) High Availability (HA) is in degraded state after mediator shows as failed/degraded/unknown in Cloud Manager CVO CLI reports that the Takeover is not...Applies to Cloud Manager Cloud Volumes ONTAP (CVO) High Availability (HA) is in degraded state after mediator shows as failed/degraded/unknown in Cloud Manager CVO CLI reports that the Takeover is not possible: Mailbox disks are not healthy in "storage failover show" node::> storage failover show Takeover Node Partner Possible State Description node-01 node-02 false Connected to node-02, node-02 node-01 false Connected to node-01, Takeover is not possible: Mailbox disks are not healthy
Reason for Storage Pool Being Unhealthy: Storage pool has more number of disks than expected. Storage Pool RAID groups and SSDs without errors: data 0a.00.2P1 0a 0 2 SA:A 0 SSD N/A 95312/195200512 953...Reason for Storage Pool Being Unhealthy: Storage pool has more number of disks than expected. Storage Pool RAID groups and SSDs without errors: data 0a.00.2P1 0a 0 2 SA:A 0 SSD N/A 95312/195200512 95320/195216896 data 0a.00.2P2 0a 0 2 SA:A 0 SSD N/A 95312/195200512 95320/195216896 data 0a.00.2P3 0a 0 2 SA:B 0 SSD N/A 95312/195200512 95320/195216896 RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) data 0a.00.2P4 0a 0 2 SA:B 0 SSD N/A 95312/195200512 95320/195216896