Why does a drive show as prefailed in Data ONTAP
Applies to
- ONTAP
- FAS Systems
- AFF Systems
Issue
The output of sysconfig -r
shows a drive in prefail status:
RAID group /aggr1/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0c.51.17 0c 51 17 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
parity 0c.52.18 0c 52 18 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
data 0c.50.18 0c 50 18 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
data 0c.53.18 0c 53 18 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
data 0c.51.18 0c 51 18 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
data 0b.57.23 0b 57 23 SA:B 0 FSAS 7200 2538546/5198943744 3815447/7814037168
data 0c.50.19 0c 50 19 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
data 0c.53.19 0c 53 19 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816 (prefail)
data 0c.51.19 0c 51 19 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
data 0c.52.19 0c 52 19 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
data 0c.50.20 0c 50 20 SA:A 0 BSAS 7200 2538546/5198943744 2543634/5209362816
- EMS message example of ONTAP determining a drive should be failed and marks it prefailed
Tue Dec 10 10:39:00 CET [node02: raidio_thread: raid.disk.predictiveFailure:error]: Disk /aggr01/plex1/rg1/3c.63.14 Shelf 63 Bay 14 [NETAPP X425_HCBEP1T2A10 NA02] S/N [XXXXXXX] UID [5000CCA0:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] reported a predictive failure and it is prefailed; it will be copied to a spare and failed