Skip to main content
NetApp Knowledge Base

Why does a drive show as prefailed in Data ONTAP

Views:
5,453
Visibility:
Public
Votes:
3
Category:
disk-drives
Specialty:
HW
Last Updated:

Applies to

  • ONTAP
  • FAS Systems
  • AFF Systems

Issue

The output of sysconfig -r shows a drive in prefail status:

    RAID group /aggr1/plex0/rg0 (normal, block checksums)

      RAID Disk	Device  	HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------	------  	------------- ---- ---- ---- ----- --------------    --------------
      dparity 	0c.51.17	0c    51  17  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      parity  	0c.52.18	0c    52  18  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      data    	0c.50.18	0c    50  18  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      data    	0c.53.18	0c    53  18  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      data    	0c.51.18	0c    51  18  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      data    	0b.57.23	0b    57  23  SA:B   0  FSAS  7200 2538546/5198943744 3815447/7814037168 
      data    	0c.50.19	0c    50  19  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      data    	0c.53.19	0c    53  19  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 (prefail)
      data    	0c.51.19	0c    51  19  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      data    	0c.52.19	0c    52  19  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      data    	0c.50.20	0c    50  20  SA:A   0  BSAS  7200 2538546/5198943744 2543634/5209362816 
      
     
  • EMS message example of ONTAP determining a drive should be failed and marks it prefailed

Tue Dec 10 10:39:00 CET [node02: raidio_thread: raid.disk.predictiveFailure:error]: Disk /aggr01/plex1/rg1/3c.63.14 Shelf 63 Bay 14 [NETAPP   X425_HCBEP1T2A10 NA02] S/N [XXXXXXX] UID [5000CCA0:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] reported a predictive failure and it is prefailed; it will be copied to a spare and failed

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.