The node fails to boot up due to DIMM fault
Applies to
- FAS2552
- ONTAP 8.3.2P2
Issue
- The node fails to boot up with MCA ERROR showing from console.
MCA ERROR
MSR:00000421:CC106380_0001009F
GFERR: 00000000
ECC error at DIMM
can be fond on SP system log.
NetApp Data ONTAP 8.3.2P2
Copyright (C) 1992-2016 NetApp.
All rights reserved.
Checking boot device filesystem
** /dev/da0s1
** Phase 1 - Read and Compare FATs
** Phase 2 - Check Cluster Chains
** Phase 3 - Checking Directories
** Phase 4 - Checking for Lost Files
63 files, 1071456 free (33483 clusters)
MARK FILE SYSTEM CLEAN? yes
MARKING FILE SYSTEM CLEAN
Retry #1 of 5: /sbin/fsck_msdosfs /dev/da0s1
Retry #2 of 5: /sbin/fsck_msdosfs /dev/da0s1
Repaired boot device filesystem
*******************************
* *
* Press Ctrl-C for Boot Menu. *
* *
*******************************
ECC error at DIMM-1: 94-01-1637-0300F965,ADDR 0x3f7e2980,(Node(0), CH(0), DIMM(0), Rank(0), Bank(0x7),Row(0x1f7c), Col(0x130)
Syndrome(Correctable Errors)DQ(63), xfer( 2)
Correctable Machine Check Error at CPU2. NB Error: STATUS(Val,MiscV,AddrV,CErrCnt(0x1),RdECC,ErrCode(Channel Unkn, Read)ErrCode(0x9f))MISC(Synd(0x38ac1608),Chan(0),DIMM(0),RTID(0x3)), ADDR(0x3f7e2980).
ECC error at DIMM-1: 94-01-1637-0300F965,ADDR 0x97dda80,(Node(0), CH(0), DIMM(0), Rank(1), Bank(0x6),Row(0x96b), Col(0x350)
Syndrome(Correctable Errors)DQ(63), xfer( 2)
…
- Output of
system helath alert show
reports DIMM creitical error.
::> system health alert show
Node: node2
Resource: DIMM-1
Severity: Critical
Indication Time: Fri Dec 22 04:54:10 2023
Suppress: false
Acknowledge: false
Probable Cause: The DIMM has reached end of life, which is leading to
memory errors.
Possible Effect: Memory issues can lead to a catastrophic system panic
which can lead to data downtime on the node.
Corrective Actions: 1. Contact technical support to obtain a new DIMM of the same specification.
2. If possible, perform a takeover of this node and bring the node down for maintenance.
3. Refer to the "DIMM replacement guide for your given hardware platform" to replace the DIMM.
4. Bring the storage system online.