The controller temperature (System Outlet) is not readable

Views:
236
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:
3/5/2025, 8:38:26 PM

Applies to

  • FAS8300
  • BMC Firmware 13.8

Issue

The controller temperature (System Outlet) is not readable

EMS
3/14/2024 14:17:35  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 13:17:35  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 12:17:35  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 11:17:35  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 10:17:34  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 09:17:34  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 08:17:34  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 07:17:34  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 06:17:34  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 05:17:34  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.
3/14/2024 09:18:02  node-01  ERROR  callhome.chassis.hitemp: Call home for CHASSIS OVER TEMPERATURE
3/14/2024 09:17:34  node-01  ERROR  monitor.temp.unreadable: The controller temperature (System Outlet) is not readable.

Environment status
System Inlet   normal     23 C  0 C  5 C   46 C   49 C     
CX5 Inlet      normal     37 C  0 C  5 C   60 C   70 C     
System Outlet  failed     -- C  0 C  5 C   58 C   61 C     
NVMe Temp      normal     25 C  0 C  5 C   60 C   70 C     
LED1 Temp      normal     23 C  0 C  3 C   43 C   46 C     
LED2 Temp      normal     23 C  0 C  3 C   43 C   46 C     
MP Temp1       normal     21 C  0 C  5 C   45 C   48 C  

SP-LATEST-IPMI
Log Collection Time: Thu Mar 21 01:55:13 2024
======================================
Self Test: (run for 0 sec)
    Selftest: passed

Sensor Reading: (run for 1 sec)
    PilotIV        | 00h | ok  |  0.1 | Dynamic MC @ 20h
    PVCCIN_CPU0    | 01h | ok  | 21.1 | 1.77 Volts
    PVCCIN_CPU1    | 02h | ok  | 21.1 | 1.77 Volts
    PVDDQ_ABC      | 03h | ok  | 21.1 | 1.21 Volts
    PVDDQ_DEF      | 04h | ok  | 21.1 | 1.21 Volts
    PVDDQ_GHI      | 05h | ok  | 21.1 | 1.21 Volts
    PVDDQ_KLM      | 06h | ok  | 21.1 | 1.21 Volts
    P1V05_PCH      | 07h | ok  | 21.1 | 1.03 Volts
    System_Inlet   | 10h | ok  |  7.1 | 22 degrees C
    CX5_Inlet      | 11h | ok  |  7.2 | 37 degrees C
    System_Outlet  | 12h | ns  |  7.3 | No Reading
    NVMe_Temp      | 13h | ok  |  7.4 | 25 degrees C

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.