Issue

Controller or Shelf chassis Fan reporting Critical errors. Examples:

  • NS224 shelf:

[ses.status.fanError:EMERGENCY]: NS224NSM100 (S/N SHFNxxxxxx) shelf 0 on channel 0x cooling fan error for Cooling element 15: critical status; fan is off. This element is on the unknown location.

[callhome.shlf.fan:EMERGENCY]: Call home for SHELF COOLING UNIT FAILED

  • DS460C shelf:

[ses.status.fanError:EMERGENCY]: DS460-12 (S/N ****) shelf 1 on channel 0a cooling fan error for Cooling element 3: critical status; fan is off. This module is on the rear of the shelf to the left.

[callhome.shlf.fan:EMERGENCY]: Call home for SHELF COOLING UNIT FAILED
 
[statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
  • DS224C shelf:

[ses.status.fanError:EMERGENCY]: DS224-12 (S/N ****) shelf 0 on channel 0b cooling fan error for Cooling element 1: critical status; fan is off. This module is on the rear of the shelf on the lower left power supply.
 [callhome.shlf.fan:EMERGENCY]: Call home for SHELF COOLING UNIT FAILED

  • DS2246 shelf:

[ses.status.temperatureInfo:info]: DS2246 (S/N ****) shelf 12 on channel 0a temperature information for Temperature sensor 4: normal status.

[monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.

  • Embed shelf in controller chassis:

::> event log show -event *fan*
... monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
... monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
... callhome.c.fan.fru.fault: Call home for CHASSIS FAN FRU FAILED: Multiple fans have failed
... monitor.globalStatus.critical: Multiple fans has failed. Power Supply Status Critical: PSU1.
... monitor.globalStatus.critical: Multiple fans has failed. Power Supply Status Critical: PSU1.
... callhome.fans.failed: Call home for MULTIPLE FAN FAILURE
... monitor.globalStatus.critical: Multiple fans has failed. Power Supply Status Critical: PSU1. Disk shelf fault.
... monitor.fan.critical: 2 fans have failed. Replace them to avoid overheating. If not corrected, system will shutdown in 2 minutes.
... monitor.fan.failed: One fan has failed.
... monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.

CTTI_NFS::> system node environment sensor show
Node Sensor     State  Value/Units ...
---- ------     -----  ----------- ...
node PSU1 Fan 1 normal 0 RPM       ...
     PSU1 Fan 2 normal 7500 RPM    ...
     PSU_FAN    fault  FAIL_1
...

  • AutoSupport STORAGE-FAULT section (or "storage show fault -v” command) shows FAN status CRITICAL Example:
Fans:
Element Status         Status Bytes  Status Descriptions
1: OK                01,05,16,A7
2: OK                01,04,50,A5
3: CRITICAL          02,01,BC,A1
4: OK                01,04,68,A5
...

             In some cases it will also show a status as "OFF, FAIL"

              Fans:
Element Status         Status Bytes  Status Descriptions
1: CRITICAL          02,00,00,F0     OFF, FAIL
2: CRITICAL          02,00,00,F0     OFF, FAIL
3: CRITICAL          02,00,00,F0     OFF, FAIL
4: CRITICAL          02,00,00,F0     OFF, FAIL
5: OK                01,05,13,A6
...

  • AutoSupport ENVIRONMENT section () shows RPM is abnromal. Example:
Cooling Unit installed element list: 1, 2, 3, 4, 5, 6, 7, 8; with error: 3
Cooling Units by element:
[1] 12840 RPM
[2] 11160 RPM
[3] 0 RPM
[4] 11130 RPM
...
  • Fan re-seat does not solve the situation

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.