EMS Alert: SHELF COOLING UNIT FAILED on Disk Shelves
Applies to
- Fan alerts
- Storage shelves
- This includes embed shelves in controller chassis
Issue
Controller or Shelf chassis Fan reporting Critical errors. Examples:
- NS224 shelf:
[ses.status.fanError:EMERGENCY]: NS224NSM100 (S/N SHFNxxxxxx) shelf 0 on channel 0x cooling fan error for Cooling element 15: critical status; fan is off. This element is on the unknown location.
[callhome.shlf.fan:EMERGENCY]: Call home for SHELF COOLING UNIT FAILED
- DS460C shelf:
[ses.status.fanError:EMERGENCY]: DS460-12 (S/N ****) shelf 1 on channel 0a cooling fan error for Cooling element 3: critical status; fan is off. This module is on the rear of the shelf to the left.
[callhome.shlf.fan:EMERGENCY]: Call home for SHELF COOLING UNIT FAILED[statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.[statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT- DS224C shelf:
[ses.status.fanError:EMERGENCY]: DS224-12 (S/N ****) shelf 0 on channel 0b cooling fan error for Cooling element 1: critical status; fan is off. This module is on the rear of the shelf on the lower left power supply.
[callhome.shlf.fan:EMERGENCY]: Call home for SHELF COOLING UNIT FAILED
- DS2246 shelf:
[ses.status.temperatureInfo:info]: DS2246 (S/N ****) shelf 12 on channel 0a temperature information for Temperature sensor 4: normal status.
[monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
- Embed shelf in controller chassis:
::> event log show -event *fan*... monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.... monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.... callhome.c.fan.fru.fault: Call home for CHASSIS FAN FRU FAILED: Multiple fans have failed... monitor.globalStatus.critical: Multiple fans has failed. Power Supply Status Critical: PSU1.... monitor.globalStatus.critical: Multiple fans has failed. Power Supply Status Critical: PSU1.... callhome.fans.failed: Call home for MULTIPLE FAN FAILURE... monitor.globalStatus.critical: Multiple fans has failed. Power Supply Status Critical: PSU1. Disk shelf fault.... monitor.fan.critical: 2 fans have failed. Replace them to avoid overheating. If not corrected, system will shutdown in 2 minutes.... monitor.fan.failed: One fan has failed.... monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
CTTI_NFS::> system node environment sensor show
Node Sensor State Value/Units ...
---- ------ ----- ----------- ...
node PSU1 Fan 1 normal 0 RPM ...
PSU1 Fan 2 normal 7500 RPM ...
PSU_FAN fault FAIL_1
...
- AutoSupport
STORAGE-FAULTsection (or "storage show fault -v” command) shows FAN statusCRITICALExample:
Fans:
Element Status Status Bytes Status Descriptions
1: OK 01,05,16,A7
2: OK 01,04,50,A5
3: CRITICAL 02,01,BC,A1
4: OK 01,04,68,A5
...In some cases it will also show a status as "OFF, FAIL"
Fans:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F0 OFF, FAIL
2: CRITICAL 02,00,00,F0 OFF, FAIL
3: CRITICAL 02,00,00,F0 OFF, FAIL
4: CRITICAL 02,00,00,F0 OFF, FAIL
5: OK 01,05,13,A6
...
- AutoSupport
ENVIRONMENTsection () shows RPM is abnromal. Example:
Cooling Unit installed element list: 1, 2, 3, 4, 5, 6, 7, 8; with error: 3
Cooling Units by element:
[1] 12840 RPM
[2] 11160 RPM
[3] 0 RPM
[4] 11130 RPM
...- Fan re-seat does not solve the situation