RAID Layout Cannot Be Autocorrected - AutoSupport message
Applies to
- ONTAP 9
- DS460
- callhome.disk.carrier.evacuation.notpossible
Event Summary
This message occurs when a system does not contain enough spares to correct existing disk failures.
- This message is seen only on systems containing disk carriers capable of holding more than one disk.
- When this message occurs, manual intervention is required because ONTAP cannot automatically correct the existing issues with the system''s disk configuration.
Validate
- Event logs will report a disk carrier evacuation not possible error:
event log show -severity alert -event *notpossible*
HA Group Notification from node_name-02 (RAID Layout Cannot Be Autocorrected Carrier: 7904453323, Disk: 3.20.13.1) ALERT
- AutoSupport alert:
[node_name-02: raid_lm: callhome.disk.carrier.evacuation.notpossible:alert]: Call home for DISK_CARRIER_EVACUATION_NOTPOSSIBLE
Resolution
- Assign any unassigned disks that are contained within a multidisk carrier.
- Add multidisk carriers.
- If a replacement carrier is available, do the following:
- Fail ALL disks within the carrier. Do not remove a multidisk carrier that contains non-failed disks; doing so results in system degradation and might result in system failure.
- Wait until the disk''s amber Attention LEDs stop flashing and are lit continuously. Do not remove a carrier while the shelf OPS panel is alternating between the shelf ID and the Attention Code H1, or while the disks within the carrier are flashing their amber Attention LEDs.
- Replace the carrier.
- Reassign partner spare disks in the HA configuration.
- If the problem persists, contact NetApp Technical Support.
Additional Information
additionalInformation_text