PSU reports DC FAIL, AC FAIL, OFF
- Views:
- 3,675
- Visibility:
- Public
- Votes:
- 0
- Category:
- disk-shelves
- Specialty:
- HW
- Last Updated:
- 4/17/2025, 8:18:43 AM
Applies to
- AFF and FAS systems
- ONTAP 9
- Power supply unit (PSU)
Issue
- EMS reports the following error message.
[Node-A: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-A: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
[Node-A: dsa_worker4: ses.status.psError:alert]: DS212-12 (S/N SHFNCXXXXXXXXXX) shelf 0 on channel 0b power error for Power supply 2: critical status; AC Fail. This module is on the rear of the shelf at the bottom right.
[Node-A: dsa_worker4: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
storage show fault
shows PSU isCRITICAL
.
Power Supplies:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F1 DC FAIL, OFF, RQSTED ON, FAIL
2: OK 01,00,00,20 RQSTED ON
OR
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F3 DC FAIL, AC FAIL, OFF, RQSTED ON, FAIL
2: OK 01,00,00,20 RQSTED ON
Fans:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F0 OFF, FAIL
2: CRITICAL 02,00,00,F0 OFF, FAIL
3: OK 01,01,2C,21
4: OK 01,01,29,21
Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
Voltage Sensors:
Element Status Status Bytes Status Descriptions
1: UNRECOVERABLE 04,00,00,00
2: UNRECOVERABLE 04,00,00,00
3: OK 01,00,01,FB
4: OK 01,00,04,C6
- The affected PSU lights amber LED.