Skip to main content
NetApp Knowledge Base

PSU on FAS or AFF shows DC undervoltage

Views:
259
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
HW
Last Updated:

Applies to

  • FAS / AFF
  • ONTAP 9

Issue

  • Single PSU shows dc-undervoltage:

::> storage shelf show -power

Power Supply Units:
Crest  Power   Reset   PSU              Operational
ID Type Part#        Serial#       Power Rating   Factor Drawn   Capable Enabled Firmware Status           PSU Location
--- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------- ------------------------
1 00 XXX-XXXXXX-XX X XXXXXXXXXXXXXX 1600         -      472     false   true    XX.XX.XX normal           rear of the shelf at the top left
2 00 XXX-XXXXXX-XX X XXXXXXXXXXXXXX 1600         -      9       false   true    XX.XX.XX dc-under-voltage rear of the shelf at the bottom left
 
  • EMS log:

Mon Jan 01 XX:XX:XX +XXXX [cluster-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.

Mon Jan 01 XX:XX:XX +XXXX [cluster-01: notifyd: asup.throttle.drop:notice]: Too many AutoSupport messages in too short a time, throttling AutoSupport: HA Group Notification from cluster-01 (SHELF POWER SUPPLY WARNING) ERROR
Mon Jan 01 XX:XX:XX +XXXX [cluster-01: dsa_workerX: ses.status.psWarning:error]: XXXXXXXXX (S/N SHFHUXXXXXXXXXX) shelf 0 on channel 0x power warning for Power supply 2: warning status; DC undervoltage. This element is on the unknown location.
Mon Jan 01 XX:XX:XX +XXXX [cluster-01: dsa_workerX: callhome.shlf.ps.fault:error]: Call home for SHELF POWER SUPPLY WARNING
  • ​​​Trap message:

2024/8/18 21:01:38 cluster cluster-01 sesShelfPowerSupplyWarn
2024/8/18 21:01:38 cluster cluster-01 sesShelfPowerSupplyWarn

  • ENVIRONMENT log:

Channel: **
 Shelf: **
 SES device path: local access: 
 Module type: IOM12; monitoring is active
 Shelf status: unrecoverable condition
 SES Configuration, shelf 10:
  logical identifier=**
  vendor identification=NETAPP
  product identification=DS212-12
  product revision level=0311
 Vendor-specific information:
  Product Serial Number: 
 Status reads attempted: 1155061; failed: 0
 Control writes attempted: 0; failed: 0
 Shelf bays with disk devices installed:
   11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
   with error: none
 Power Supply installed element list: 1, 2; with error: 2

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.