Skip to main content
NetApp Knowledge Base

PCI Error NMI from device(s): PLX PCIE 8764 switch on Controller due to NVRAM Module failed

Views:
75
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • AFF-A700

Issue

  • ONTAP cluster node reboots unexpectedly:
PANIC: PCI Error NMI from device(s):ErrSrcID(CorrSrc(0x5f48),UCorrSrc(0)), RPT(0,3,0):PLX PCIE 8764 switch in slot 6 on Controller.  in process idle: cpu6 on release 9.12.1P3 (C) on Sun May 18 22:55:48 JST 2025
  • The slot of NVRAM Module is located by analyze tool.
  • Both of two DIMMs show failed.
environ -show_all
=================
Sensor Name              State          Current    Critical     Warning     Warning    Critical
Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
NVS DIMM0 Temp           failed            -- C         0 C         5 C        80 C        85 C
NVS DIMM1 Temp           failed            -- C         0 C         5 C        80 C        85 C

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.