Skip to main content
NetApp Knowledge Base

ONTAP reports a callhome.dsk.redun.fault event

Views:
8
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • DS212-12
  • IOM12
  • X336_TTCRE04TA07

Issue

  • The event log shows callhome.dsk.redun.fault: Call home for DISK REDUNDANCY FAILED

Node: node1
Sequence#: 583106
Time: 4/9/2026 01:58:33
Severity: ERROR
Source: dsa_disc
Message Name: callhome.dsk.redun.fault
Event: callhome.dsk.redun.fault: Call home for DISK REDUNDANCY FAILED
Corrective Action: Locate disks which have lost redundancy by using the following command: "storage disk show -fields disk,primary-port,secondary-name,secondary-port,shelf,bay" Note all channels with single path connectivity. Check for failures using these commands: "system health node-connectivity shelf show" and "system health system-connectivity shelf show". If a module or cable failure is identified, replace the failed module or cable. Confirm redundancy has been restored with the following command: "storage disk show -fields disk,primary-port,secondary-name,secondary-port,shelf,bay" If you need assistance, contact NetApp technical support.
Description: This message occurs when redundant access to disk storage is lost. This message and associated Autosupport are issued at most once per day. If your system is configured to do so, it generates and transmits an AutoSupport (or 'call home') message to NetApp technical support and to the configured destinations. Successful delivery of an AutoSupport message significantly improves problem determination and resolution.

  • System warning LED is illuminated
  • Disk 2.11.4 shows fewer paths than other disks, instead of the expected redundant paths

cluster::> storage disk show -disk 2.11.4 -instance
                  Disk: 2.11.4                                        
        Container Type: aggregate
            Owner/Home: node2 / node2
               DR Home: -
    Stack ID/Shelf/Bay: 2  / 11 / 4
                   LUN: 0
                 Array: N/A
                Vendor: NETAPP
                 Model: X336_TTCRE04TA07
         Serial Number: xxxxxx93F9XC
                   UID: xxxxxxxx:xxxxxxxxx
                   BPS: 520
         Physical Size: 3.64TB
              Position: data
Checksum Compatibility: block
             Aggregate: node2_aggr02
                  Plex: plex0
Paths:
                                LUN  Initiator Side        Target Side                                                                              Link
Controller         Initiator     ID  Switch Port           Switch Port           Acc Use  Target Port              TPGN    Speed      I/O KB/s          IOPS
------------------ ---------  -----  --------------------  --------------------  --- ---  -----------------------  ------  -------  ------------  ------------
node2        2a             0  N/A                   N/A                   AO  INU  xxxxxxxxxxxxd2a9             48  12 Gb/S           132             1
node1        0d             0  N/A                   N/A                   AO  INU  xxxxxxxxxxxxd2a9             48  12 Gb/S             0             0
 
Errors:
-

cluster::> storage disk show -disk 2.11.3 -instance
                  Disk: 2.11.3                                        
        Container Type: aggregate
            Owner/Home: node2 / node2
               DR Home: -
    Stack ID/Shelf/Bay: 2  / 11 / 3
                   LUN: 0
                 Array: N/A
                Vendor: NETAPP
                 Model: X336_TTCRE04TA07
         Serial Number: xxxxxx95F9XC
                   UID: xxxxxxxx:xxxxxxxx
                   BPS: 520
         Physical Size: 3.64TB
              Position: data
Checksum Compatibility: block
             Aggregate: node2_aggr02
                  Plex: plex0
Paths:
                                LUN  Initiator Side        Target Side                                                                              Link
Controller         Initiator     ID  Switch Port           Switch Port           Acc Use  Target Port              TPGN    Speed      I/O KB/s          IOPS
------------------ ---------  -----  --------------------  --------------------  --- ---  -----------------------  ------  -------  ------------  ------------
node2        0d             0  N/A                   N/A                   AO  INU  xxxxxxxxxxxxd2c6             56  12 Gb/S             0             0
node2        2a             0  N/A                   N/A                   AO  RDY  xxxxxxxxxxxxd2c5             25  12 Gb/S             0             0
node1        0d             0  N/A                   N/A                   AO  INU  xxxxxxxxxxxxd2c5             25  12 Gb/S             0             0
node1        2a             0  N/A                   N/A                   AO  RDY  xxxxxxxxxxxxd2c6             56  12 Gb/S             0             0
 
Errors:
-

  • Disk 2.11.4 is missing from sysconfig -a

node1

            slot 2: SAS Host Adapter 2a (Broadcom SAS3616W rev. 2, SAS, <UP>)
                        Firmware rev:      17.00.00.00
                        NVDATA rev:        17.01.00.11
                        Base WWN:          xxxxxxxxxxxxxxxxx
                        Temperature:       Not Available
                        MFG Part Number:   111-04226
                        Board Name:        HBA 9405W-16e
                        Assembly:          03-50044-10006
                        Serial number:     xxxxxxxxx
                        Phy State:         [0] Enabled, 12.0 Gb/s
                                           [1] Enabled, 12.0 Gb/s
                                           [2] Enabled, 12.0 Gb/s
                                           [3] Enabled, 12.0 Gb/s
                        Mini-SAS HD Vendor:        Amphenol
                        Mini-SAS HD Part Number:   112-00437+A0
                        Mini-SAS HD Type:          Passive Copper (unequalized) 2m end_1
                        Mini-SAS HD Serial Number: xxxxxxxxx00664
                        11.0 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx97F9XC)
                        11.1 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx5F9XC)
                        11.2 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB8F9XC)
                        11.3 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx95F9XC)
                        11.5 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx98F9XC)
                        11.6 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9TF9XC)
                        11.7 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB0F9XC)
                        11.8 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9NF9XC)
                        11.9 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9GF9XC)
                        11.10: NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9JF9XC)
                        11.11: NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx99F9XC)
                        Shelf 11: DS212-12  Firmware rev. IOM12 A: 0281  IOM12 B: 0281

node2

            slot 0: SAS Host Adapter 0d (Broadcom SAS3616W rev. 2, SAS, <UP>)
                        Firmware rev:      12.00.00.00
                        NVDATA rev:        12.03.01.02
                        Base WWN:          xxxxxxxxxxxxxxxxx
                        Temperature:       Not Available
                        Phy State:         [0] Enabled, 12.0 Gb/s
                                           [1] Enabled, 12.0 Gb/s
                                           [2] Enabled, 12.0 Gb/s
                                           [3] Enabled, 12.0 Gb/s
                        Mini-SAS HD Vendor:        Amphenol
                        Mini-SAS HD Part Number:   112-00437+A0
                        Mini-SAS HD Type:          Passive Copper (unequalized) 2m end_1
                        Mini-SAS HD Serial Number: xxxxxxxxx00859
                        11.0 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx97F9XC)
                        11.1 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx5F9XC)
                        11.2 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB8F9XC)
                        11.3 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx95F9XC)
                        11.5 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx98F9XC)
                        11.6 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9TF9XC)
                        11.7 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB0F9XC)
                        11.8 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9NF9XC)
                        11.9 : NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9GF9XC)
                        11.10: NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9JF9XC)
                        11.11: NETAPP   X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx99F9XC)
                        Shelf 11: DS212-12  Firmware rev. IOM12 A: 0281  IOM12 B: 0281

  • Disk 2.11.4 is bypassed by Module B, as shown in storage show fault -v

Enclosure Status: non-critical
Channel: 0d
Shelf: 11
Shelf Type: DS212-12
Product Serial Number: xxxxxxxxxxxxx
Module Type: IOM12

Disk Elements:
Element Status                  Status Bytes  Status Descriptions
  4 [Bay  4]: NONCRITICAL       03,04,10,04   ENCLOSURE BYPASSED B, BYPASSED B

  • Condition clears after storage restart

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.