Node led on with ACP error
Applies to
- FAS2554
- Alternate control path (ACP)
Issue
- Node led on
- storage show faultreports ACP is critical.
node1> storage show fault -v
Disk Elements:
Element Status                  Status Bytes  Status Descriptions
  0 [Bay  0]: OK                01,00,00,00
  1 [Bay  1]: OK                01,01,00,00
  2 [Bay  2]: OK                01,02,00,00
  3 [Bay  3]: OK                01,03,00,00
  4 [Bay  4]: OK                01,04,00,00
  5 [Bay  5]: OK                01,05,00,00
  6 [Bay  6]: NOT INSTALLED     05,06,00,00   
...
Vendor Unique Element 83-IOM6E: (SAS)
Element Status         Status Bytes  Status Descriptions
  1 [IOM6E A]    : OK                01,08,00,00   MASTER
  2 [IOM6E B]    : OK                01,00,00,00
Vendor Unique Element 85-IOM6E: (ACP)
Element Status                      Status Bytes  Status Descriptions
  1 [IOM6E A]    : OK                01,10,00,00   INBACP
  2 [IOM6E B]    : CRITICAL          02,10,00,40   INBACP, FAIL   
[Status changed from Pending Customer to Active]