Node Shutdown Due to “Battery Current Critical” – Emergency Shutdown
Applies to
- FAS8300
- FAS8700
- AFF A400
- AFF C400
- ASA A400
- ASA C400
- ONTAP 9
Issue
- A FAS8300 node unexpectedly shut down with the following error observed in the system log:
May 13 00:52:50 clustername [nodename-02:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery current critical)Additional observations:
-
The system battery was reported as “Ready” with 100% relative charge, but the absolute charge was lower (e.g., 74%).The last battery learning cycle took an abnormally long time (from 04/29 to 05/12).
BMC nodename> system battery showDeviceChemistry : LIONChemistryID : 0x1267SerialNumber : 0x53c6Status : ReadyCurrent : 0 mATemperature : 19.45 CVoltage : 8032 mVMaxError : 1 %RemainingCapacity : 1554 mAhFullChargeCapacity: 1554 mAhRelativeCharge : 100 %AbsoluteCharge : 74 %Bat_Dstg_Cycles : 17...LrnCycleStartDate : 26-04-29-15:31LrnCycleStartFCC : 0x0631LrnCycleEndFCC : 0x0622LrnCycleEndDate : 26-05-12-15:48