Applies to

  • ONTAP 9
  • AFF A800, AFF A400, AFF A320
  • FAS8700, FAS8300
  • NVDIMM
    • Health Status Explanation: VPP Lost 

Issue

EMS Log:

Tue Apr 11 13:53:17 -0400 [NetApp1: nphmd: hm.alert.raised:alert]: Alert Id = NVDIMMBadHealthAlert , Alerting Resource = /dev/nvdimm0:NetApp1 raised by monitor controller

AutoSupport logs, we see the following:

  • PLATFORM-SENSORS.XML

---------------------------------------------------------------
Sensor Name     Sensor Type      Sensor State
--------------------------------------------------------------
NVDIMM0 VPP      discrete      fault
NVDIMM0 Health   discrete      fault

 

  • NVDIMM-STATUS

Total NVDIMM on this platform is 1
--------------------------------------------------
DIMM(/dev/nvdimm0) Page:0
--------------------------------------------------
0x0000: 00 0a 0a 01 01 00 21 3c   25 3c 25 34 34 00 00 00
0x0010: 1f 2e 00 00 03 15 03 0b   68 81 02 00 68 81 1e 80
0x0020: 05 80 78 80 05 00 00 40   1f ac 0d d0 07 a0 0f 90
0x0030: 33 08 08 dc 05 10 80 00   00 00 70 03 00 00 00 00
0x0040: 00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00
0x0050: 00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00
-----------------------------------------------------
--------------------------------------------------
DIMM(/dev/nvdimm0):
--------------------------------------------------
  Controller Ready: Yes
  Controller Busy: No
  Energy Policy managed by: HOST
  Save_N Low During CSAVE: Yes
  Save_N Enabled(ARMED): Yes
  Data on the Flash: NotValid

  Module is Health: No
  Module Status(0x0004): VPP Lost 
  Flash Lifetime: 96%
  Flash Lifetime Status: Normal

Health Alert:

::>system health alert show

Node Node01
Monitor controller
Alert ID NVDIMMBadHealthAlert
Alerting Resource /dev/nvdimm0:NetApp1
Subsystem Motherboard
Indication Time Tue Apr 11 13:53:17 2023
Perceived Severity Major
Probable Cause hardware_degrading
Description NVDIMM "NVDIMM-N 0 (DIMM-11)" on node "NetApp1" is indicating a degraded status.
Corrective Actions Contact technical support for assistance with NVDIMM module replacement.
Possible Effect Potential data loss as the NVDIMM becomes degraded.
Acknowledge false
Suppress false
Policy NVDIMMBadHealthPolicy
Additional Information

Node: NetApp1
Unique Name: /dev/nvdimm0:NetApp1 
Device Name and DIMM Slot: /dev/nvdimm0
Health Status: degraded
Health Status Explanation: VPP Lost 
Lifetime Status: NORMAL
Lifetime Status Explanation: None

  • Reboot of the node doesn't fix the issue.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.