Skip to main content
NetApp Knowledge Base

NVDIMM Temperature not readable in AFF A900 due to NVRAM module

Views:
141
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
hw
Last Updated:

This knowledge base was generated through a script and may contain formatting issues. For the accurate content, please refer to the WIP editor. WIP editor.

Applies to

  • AFF A900
  • NVRAM module

Issue

Node was continuously triggering the temperature sensor unreadable errors on NVDIMMs.

  • CONSOLE-LOGS (During the boot process)

node1:monitor.temp.unreadable:error]: The controller temperature (PM40068B Temp) is not readable.
node1:monitor.temp.unreadable:error]: The controller temperature (FPGA Temp 0) is not readable.
node1:monitor.temp.unreadable:error]: The controller temperature (FPGA Temp 1) is not readable.
node1:monitor.temp.unreadable:error]: The controller temperature (NV M.2 Temp) is not readable.
node1:monitor.temp.unreadable:error]: The controller temperature (NVDIMM 1 Temp) is not readable.
node1:monitor.temp.unreadable:error]: The controller temperature (NVDIMM 2 Temp) is not readable.

 

  • Environment-Sensor
         PM40068B Temp         not-available - C          0        1      95     1
         VBAT P8V              not-available - mV      7000     7400    8550    89
         HS VOUT               not-available - mV     10560    11160   12840   134
         HS Current            not-available - mA         0     1000   14000   150
         NV DIMM1 CECC Count   not-available - cycles     -        -       -
         NV DIMM2 CECC Count   not-available - cycles     -        -
  • BMC-LOGS (bmc status -d)
​​cat /mnt/logs/frumsgs
=====================
node1 fru_mond[1044]: [ERROR]Start locater is incorrect 0xffffffff
node1 fru_mond[1044]: [ERROR]Platform VPD Header is corrupted on fru NVS
node1 fru_mond[1044]: [ERROR]Could not read platform vpd header information
node1 fru_mond[1044]: [ERROR]Start locater is incorrect 0xffffffff
node1 fru_mond[1044]: [ERROR]Platform VPD Header is corrupted on fru NVS
node1 fru_mond[1044]: [ERROR]Could not read platform vpd header information

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.