Applies to

  • AFF A1K, AFF A90, AFF A70
  • ASA A1K, ASA A90, ASA A70
  • FAS90, FAS70
  • AFF A900, ASA A900
  • FAS9500
  • platform.reducedMemory event

Issue

  • "BootDimmDisableAlert" reported for multiple DIMMs from system health alert show

Node: node-01
Alert ID: BootDimmDisableAlert
Resource: DIMM-10
Severity: Major
Indication Time: XXX XXX XX XX:XX:XX XXXX

Suppress: false
Acknowledge: false
Probable Cause: "DIMM-10" has been disabled to preserve memory
interleaving. The system has booted with less memory.
Possible Effect: System memory has been reduced, which can impact
performance of the node.
Corrective Actions: Repair failed or mapped-out DIMMs in the system. Then,
reset the system to re-enable disabled DIMMs.

  • ECC error, other POST memory errors and platform.reducedMemory event can be found in the serial console log.

login: ECC error at DIMM-23: 2204-0278F989,ADDR 0x6296b70340,(Node(0), memory controller(3), CH(6), DIMM(0), Rank(1), Bank Group(2), Bank(0x3), Row(0x1885e), Col(0x208)) Uncorrectable Machine Check Error at CPU29. ICL_IMC3_C0 Error: STATUS<0xbe00ffc2001000c0>(VALID,UC,EN,MISCV,ADDRV,PCC,CORR_ERR_STAT(0),CORR_ERR_CNT(0x3ff),OTHER_INFO(0x2),MSCOD(0x10),MCACOD(0xc0)),MISC<0x09000e0c42f10486>(EXTRA_ERR_INFO(0x4800706217882),ADDR_MODE(0x2),REC_ERR_LSB(0x6)),ADDR<0x0000006296b70340>(ADDRESS(0x6296b70340))Node(0), Memory controller(3), CH(0), DIMM(0), Rank(1), Bank Group(2), Bank(0x3), Row(0x1885e), Col(0x208),

MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
DIMM:23 mapped out. BIOS MRC mapped out DIMM. Major / Minor Error Code: 0x0B / 0x1C
Complete channel mapped out.
Or 
DIMM:23 mapped out. BIOS MRC mapped out DIMM. Major / Minor Error Code: 0x30 / 0x2D
Complete channel mapped out.

DIMM in slot 3 is disabled
DIMM in slot 7 is disabled
DIMM in slot 10 is disabled
DIMM in slot 14 is disabled
DIMM in slot 19 is disabled
DIMM in slot 23 failed
DIMM in slot 26 is disabled
DIMM in slot 30 is disabled
Jan 23 23:58:06 [node-01:platform.reducedMemory:ALERT]: System memory (511 GB) is less than expected (1024 GB). Check DIMMs slots 3, 7, 10, 14, 19, 23, 26, 30.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.