Multiple DIMMs disabled due to one DIMM failure, ONTAP boots with less memory
Applies to
- AFF A1K, AFF A90, AFF A70, AFF C80, AFX 1K
- ASA A1K, ASA A90, ASA A70
- FAS90, FAS70
- AFF A900, ASA A900
- FAS9500
- platform.reducedMemory event
Issue
- "
BootDimmDisableAlert" reported for multiple DIMMs fromsystem health alert show
Node: node-01
Alert ID: BootDimmDisableAlert
Resource: DIMM-10
Severity: Major
Indication Time: XXX XXX XX XX:XX:XX XXXX
Suppress: false
Acknowledge: false
Probable Cause: "DIMM-10" has been disabled to preserve memory
interleaving. The system has booted with less memory.
Possible Effect: System memory has been reduced, which can impact
performance of the node.
Corrective Actions: Repair failed or mapped-out DIMMs in the system. Then,
reset the system to re-enable disabled DIMMs.
- ECC error, other POST memory errors and
platform.reducedMemoryevent can be found in the serial console log.
login: ECC error at DIMM-23: 2204-0278F989,ADDR 0x6296b70340,(Node(0), memory controller(3), CH(6), DIMM(0), Rank(1), Bank Group(2), Bank(0x3), Row(0x1885e), Col(0x208)) Uncorrectable Machine Check Error at CPU29. ICL_IMC3_C0 Error: STATUS<0xbe00ffc2001000c0>(VALID,UC,EN,MISCV,ADDRV,PCC,CORR_ERR_STAT(0),CORR_ERR_CNT(0x3ff),OTHER_INFO(0x2),MSCOD(0x10),MCACOD(0xc0)),MISC<0x09000e0c42f10486>(EXTRA_ERR_INFO(0x4800706217882),ADDR_MODE(0x2),REC_ERR_LSB(0x6)),ADDR<0x0000006296b70340>(ADDRESS(0x6296b70340))Node(0), Memory controller(3), CH(0), DIMM(0), Rank(1), Bank Group(2), Bank(0x3), Row(0x1885e), Col(0x208),
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
MEMORY WARNING: Major Code 0x30 Minor Code 0x2D Dimm 23
DIMM:23 mapped out. BIOS MRC mapped out DIMM. Major / Minor Error Code: 0x0B / 0x1C
Complete channel mapped out.
Or
DIMM:23 mapped out. BIOS MRC mapped out DIMM. Major / Minor Error Code: 0x30 / 0x2D
Complete channel mapped out.
DIMM in slot 3 is disabled
DIMM in slot 7 is disabled
DIMM in slot 10 is disabled
DIMM in slot 14 is disabled
DIMM in slot 19 is disabled
DIMM in slot 23 failed
DIMM in slot 26 is disabled
DIMM in slot 30 is disabled
Jan 23 23:58:06 [node-01:platform.reducedMemory:ALERT]: System memory (511 GB) is less than expected (1024 GB). Check DIMMs slots 3, 7, 10, 14, 19, 23, 26, 30.
- In ASUP’s
DIMM-INFO.XML log, the output can be seen below
Example(AFF-C80):2 DIMM-2 0 2 0 Samsung-13ABFD3C M321R4GA3BB6-CQKET 0 0 controller unknown DIMM-2 DIMM-2 bucket false disabled4 DIMM-4 0 0 0 Samsung-13ABD70D M321R4GA3BB6-CQKET 0 0 controller ok DIMM-4 DIMM-4 bucket false none5 DIMM-5 0 4 0 Samsung-13AC01D4 M321R4GA3BB6-CQKET 0 0 controller unknown DIMM-5 DIMM-5 bucket false disabled7 DIMM-7 0 6 0 Samsung-13ABFD3D M321R4GA3BB6-CQKET 0 0 controller ok DIMM-7 DIMM-7 bucket false none10 DIMM-10 1 2 0 Samsung-13AC0269 M321R4GA3BB6-CQKET 0 0 controller unknown DIMM-10 DIMM-10 bucket false fault12 DIMM-12 1 0 0 Samsung-13AC0232 M321R4GA3BB6-CQKET 0 0 controller ok DIMM-12 DIMM-12 bucket false none13 DIMM-13 1 4 0 Samsung-13ABF48B M321R4GA3BB6-CQKET 0 0 controller unknown DIMM-13 DIMM-13 bucket false disabled15 DIMM-15 1 6 0 Samsung-13ABFCBA M321R4GA3BB6-CQKET 0 0 controller ok DIMM-15 DIMM-15 bucket false none