Mixing SAS and FSAS disks in the same aggregate is not supported
- Views:
- 1,846
- Visibility:
- Public
- Votes:
- 0
- Category:
- clustered-data-ontap-8
- Specialty:
- HW
- Last Updated:
- 8/9/2022, 11:55:46 AM
Applies to
- ONTAP 9
- FAS8200
- Product Model : FAS2552A-SSA-R6
Answer
- Data ONTAP classifies disks based on performance vs capacity and does not allow mixing.
- When attempting to add an FSAS disk to an aggregate made of SAS disk drives, the following error is displayed
Error: command failed: Failed to add disks to aggregate.
Reason: Disk type does not match type of disks in the aggregate.
- For more information on how Data ONTAP selects disks for aggregate creation, see KB: How does Data ONTAP select spares for aggregate creation, aggregate addition, and failed disk replacement?