MixedDomainFromNodeToSwitch_Alert seen from switch attached NS224 shelf
Applies to
- ONTAP 9
- Switch attached storage
- NS224 Shelf
Issue
- MixedDomainFromNodeToSwitch health alert reported following node reboot
- Switch attached NS224 shelves report multi-path
- 
    MixedDomainFromSwitchToShelf_Alertmessages:[node_name: schmd: hm.alert.raised:alert]: Alert Id = MixedDomainFromSwitchToShelf_Alert , Alerting Resource = switch_name-a(ABC123456D7) raised by monitor system-connect[node_name: schmd: hm.alert.raised:alert]: Alert Id = MixedDomainFromSwitchToShelf_Alert , Alerting Resource = switch_name-b(ABC123456D8) raised by monitor system-connect- System health alert:
 ::> system health alert show
 Node: node_name
 Alert ID: MixedDomainFromSwitchToShelf_Alert
 Resource: Switch name: switch_name-a(ABC123456D7)
 Severity: Minor
 Indication Time: Tue Jan 10 12:10:02 2023
 Suppress: false
 Acknowledge: false
 Probable Cause: Storage Switch switch_name-a is connected to shelves 3.20,
 3.30 with mixed domains.
 Possible Effect: This issue will affect conversions to direct-attached
 storage.
 Corrective Actions: Connect the switch node_name to both shelves with the
 same storage domain, following the guide applicable to
 your shelf.
 Node: node_name
 Alert ID: MixedDomainFromSwitchToShelf_Alert
 Resource: Switch name: switch_name-b(ABC123456D8)
 Severity: Minor
 Indication Time: Tue Jan 10 12:10:02 2023
 Suppress: false
 Acknowledge: false
 Probable Cause: Storage Switch switch_name-b is connected to shelves 3.20,
 3.30 with mixed domains.
 Possible Effect: This issue will affect conversions to direct-attached
 storage.
 Corrective Actions: Connect the switch node_name to both shelves with the
 same storage domain, following the guide applicable to
 your shelf.
 2 entries were displayed.- "system health subsystem show" shows "SAS-connect_Cluster degraded" after system reboot Example:
 ::> system health subsystem show
 Subsystem Health
 ----------------- ------------------
 SAS-connect ok
 ...
 FHM-Bridge ok
 SAS-connect_Cluster degraded
 13 entries were displayed.::*> system health subsystem show -instance -subsystem SAS-connect_Cluster
 Subsystem: SAS-connect_Cluster
 Health: unknown
 Initialization State: start_discovery
 Number of Outstanding Alerts: 0
 Number of Suppressed Alerts: 0
 Node: node_name
 Subsystem Refresh Interval: 30m