Issue

  • MixedDomainFromNodeToSwitch health alert reported following node reboot
  • Switch attached NS224 shelves report multi-path
  • MixedDomainFromSwitchToShelf_Alert messages:

    [node_name: schmd: hm.alert.raised:alert]: Alert Id = MixedDomainFromSwitchToShelf_Alert , Alerting Resource = switch_name-a(ABC123456D7) raised by monitor system-connect

    [node_name: schmd: hm.alert.raised:alert]: Alert Id = MixedDomainFromSwitchToShelf_Alert , Alerting Resource = switch_name-b(ABC123456D8) raised by monitor system-connect

    • System health alert

    ::> system health alert show
                Node: node_name
            Alert ID: MixedDomainFromSwitchToShelf_Alert
            Resource: Switch name: switch_name-a(ABC123456D7)
            Severity: Minor
     Indication Time: Tue Jan 10 12:10:02 2023
            Suppress: false
         Acknowledge: false
      Probable Cause: Storage Switch switch_name-a is connected to shelves 3.20,
                      3.30 with mixed domains.
     Possible Effect: This issue will affect conversions to direct-attached
                      storage.
     Corrective Actions: Connect the switch node_name to both shelves with the
                      same storage domain, following the guide applicable to
                      your shelf.
                Node: node_name
            Alert ID: MixedDomainFromSwitchToShelf_Alert
            Resource: Switch name: switch_name-b(ABC123456D8)
            Severity: Minor
     Indication Time: Tue Jan 10 12:10:02 2023
            Suppress: false
         Acknowledge: false
      Probable Cause: Storage Switch switch_name-b is connected to shelves 3.20,
                      3.30 with mixed domains.
     Possible Effect: This issue will affect conversions to direct-attached
                      storage.
     Corrective Actions: Connect the switch node_name to both shelves with the
                      same storage domain, following the guide applicable to
                      your shelf.
    2 entries were displayed.

    • "system health subsystem show" shows "SAS-connect_Cluster  degraded" after system reboot Example:

    ::> system health subsystem show
     Subsystem Health
     ----------------- ------------------
     SAS-connect ok
     ...
     FHM-Bridge ok
     SAS-connect_Cluster  degraded
     13 entries were displayed.

    ::*> system health subsystem show -instance -subsystem SAS-connect_Cluster
                    Subsystem: SAS-connect_Cluster
                       Health: unknown
         Initialization State: start_discovery
    Number of Outstanding Alerts: 0
     Number of Suppressed Alerts: 0
                         Node: node_name
      Subsystem Refresh Interval: 30m

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.