In case the Administrator needs those changes to be reflected immediately, the cache will have to be flushed manually. The following set of commands flushes multiple entries of netgroups which will fo...In case the Administrator needs those changes to be reflected immediately, the cache will have to be flushed manually. The following set of commands flushes multiple entries of netgroups which will force the vServer to fetch the whole data back from the Name-Services. The command 'export-policy cache flush' must be issued from the node that owns the cache, thus; by logging in to a management LIF on each node. To flush the entire ip to netgroup cache on the vserver
Data ONTAP classifies disks based on performance vs capacity and does not allow mixing. When attempting to add an FSAS disk to an aggregate made of SAS disk drives, the following error is displayed Re...Data ONTAP classifies disks based on performance vs capacity and does not allow mixing. When attempting to add an FSAS disk to an aggregate made of SAS disk drives, the following error is displayed Reason: Disk type does not match type of disks in the aggregate. For more information on how Data ONTAP selects disks for aggregate creation, see KB: How does Data ONTAP select spares for aggregate creation, aggregate addition, and failed disk replacement?
Port pairs connected to the same ASIC must be configured in the same mode. Note: After changing the mode type of one port, the other port also gets changed. aff::> system node hardware unified-connect...Port pairs connected to the same ASIC must be configured in the same mode. Note: After changing the mode type of one port, the other port also gets changed. aff::> system node hardware unified-connect modify -node aff-01 -adapter 0c -mode cna -type target -force true.Any changes will take effect after rebooting the system. Therefore, it is not possible to configure one port in a UTA2 port pair as FC target/initiator and the other port in the CNA (FCoE target/Ethernet) mode.