Skip to main content
NetApp Knowledge Base

Missing Sensor Information After Manual SP Reboot on FAS8200

Views:
53
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8200
  • ONTAP 9

Issue

  • After a manual Service Processor (SP) reboot, some sensor information is missing or unreadable in ONTAP.
  • The issue was observed following an earlier alert:

HA Group Notification from naspb13 (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2.)

  • Although the PSU status returned to normal, subsequentsystem node environment sensors show output displayed missing or abnormal sensor values.

cluster::*> sensors show
Node Sensor State Value/Units
-------------------------------------------------------
node01 PSU2 normal GOOD
node01 PSU1 normal GOOD

cluster::*> sensors show
  (system node environment sensors show)
Node Sensor                 State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
node01
     PSU2                  normal
                                         GOOD
     PSU1                  normal
                                         GOOD
     Fan3                  normal
                                         GOOD
     Fan2                  normal
                                         GOOD
     Fan1                  normal
                                         GOOD
     SP Status             normal
                                   IPMI_HB_OK
     mSATA Status          normal
                                           OK
     mSATA Pres            normal
                                      PRESENT
node02
     PSU2                  normal
                                         GOOD
     PSU1                  normal
                                         GOOD
     Fan3                  normal
                                         GOOD
     Fan2                  normal
                                         GOOD
     Fan1                  normal
                                         GOOD
     SP Status             normal
                                   IPMI_HB_OK
     mSATA Status          normal
                                           OK
     mSATA Pres            normal
                                      PRESENT
     CPU0 Temp Margin      normal
                                      -57 C          -        -     -11      -1
     In Flow Temp          normal
                                       25 C          0        5      50      55
     Out Flow Temp         normal
                                       39 C          0        5      65      75
     PCI Slot Temp         normal
                                       35 C          0        5      60      70
     Smart Bat Temp        normal
                                       31 C          0        5      60      70
     CPU0 Error            normal
                                       NORMAL
     CPU0 Therm Trip       normal
                                       NORMAL
     CPU0 Hot              normal
                                       NORMAL
     Memory0 Hot           normal
                                       NORMAL
     PCH Hot               normal
                                       NORMAL
     Ambient Temp 1        normal
                                       23 C          0        5      47      52
     Ambient Temp 2        normal
                                       23 C          0        5      47      52
     P5V STBY              normal
                                     5099 mV      4245     4343    5660    5807
     P3.3V STBY            normal
                                     3280 mV      2960     3040    3568    3664
     P1.8V STBY            normal
                                     1794 mV      1629     1658    1949    1969
     P1.2V STBY            normal
                                     1193 mV      1086     1105    1299    1319
     P0.9V STBY            normal
                                      882 mV       805      853     950     999
  • Additionally, repeated BMC/SP event logs showed:

[ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Sent

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.