Internal shelf reporting under temperature warning while partner node down
Applies to
- FAS2620
- FAS2720
Issue
- One node down and surviving partner node show under temperature warning.
EMS:
[?] Tue Jul 18 09:00:00 JST [cl1-02: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
ENVIRONMENT:
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: 11
Shelf temperatures by element:
[1] 17 C (62 F) (ambient) Normal temperature range
[2] 24 C (75 F) Normal temperature range
[3] 24 C (75 F) Normal temperature range
[4] 25 C (77 F) Normal temperature range
[5] 25 C (77 F) Normal temperature range
[6] 24 C (75 F) Normal temperature range
[7] 26 C (78 F) Normal temperature range
[8] 26 C (78 F) Normal temperature range
[9] 26 C (78 F) Normal temperature range
[10] 28 C (82 F) Normal temperature range
[11] 0 C (32 F) Undertemperature warning!
STORAGE-SHELF.XML
shows issued sensor located at the down node.