How to obtain TruFOS Certificate for Brocade switches
Applies to
Brocade Switches
Description
-
The TruFOS license is linked to the support contract.
-
The TruFOS certificate when generated will run through to the end of the active support contract.
-
license --show
output confirms if an TruFOS certificate is expired.
/fabos/link_sbin/license --show:
License Id : 10:00:xx:xx:xx:xx:xx:xx
License 1 :
-------------------------------------------------------------
License serial number : FOS-86-0-04-11xxxx54
License features : Trusted FOS (TruFOS) Certificate
Generation date : 12/07/2022
Expiry date : 01/06/2023
License has expired
-
Upgrading to latest version fail when the TruFOS certificate is not installed and can be verified by the above command
license --show
ERROR: TruFOS validation failed. Please install a valid TruFOS and run firmwaredownload again
-
These licenses are generated from the Broadcom portal for the respective serial number.
-
Brocade TruFOS Certificates are required on the following platforms, starting with Fabric OS v9.1.0:
-
Brocade Gen 6 Directors
-
Brocade Gen 7 Directors
-
Brocade Gen 6 G630 (switch types 173 and 184)
-
Brocade Gen 7 G730 Switches
-
- Brocade TruFOS Certificates are required on the following platforms, starting with Fabric OS v9.2.0:
- G720
- 7850
- G620
- G610
- 7810