How do four PSUs power controller in AFF A400, C400,FAS8300,FAS8700?

Views:
124
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • AFF A400, AFF C400
  • ASA A400, ASA C400
  • FAS8300
  • FAS8700

Answer

  • This platform has 4 x Power Supply (PSU)s per system.
    • PSUs are plugged directly into the Processor Controller Module (PCM) (2 per canister).
    • PSUs power the midplane and if a failure occurs, will also power the partner PCM.
  • 2+2 configuration
    • Require power to at least 2 PSUs at all times for proper system operation.
    • The Platforms will remain operational with up to 2 PSU failures.
      • More than 2 will initiate a Takeover to the Partner or will shutdown on a Single node cluster.
    • Power from each PSU is delivered throughout the system (midplane, fans, partner PCM, local PCM).

Additional Information

additionalInformation_text
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.