  • FAS2520 / FAS2552 / FAS2554

Issue

  • Node reboots unexpectedly
  • Node does not reboot after an unexpected shutdown

Service Processor logs on the impacted node show the following:

Record 801: Sun Mar 06 15:09:20.924775 2021 [IPMI Event.critical]: L2 watchdog timeout hard reset
Record 802: Sun Mar 06 15:09:20.984259 2021 [Trap Event.critical]: hwassist l2_watchdog_reset (29)
Record 803: Sun Mar 06 15:09:23.000822 2021 [SP.critical]: Filer Reboot

  • If node reboots, the following error can be seen in the EMS log files

[cluster-01:mgr.boot.reason_abnormal:EMERGENCY]: System rebooted due to a watchdog reset.

  • If node is unable to reboot, system senors from the SP may show senors unavailble (na) or faulted (Fault)

Sensor Name      | Current    | Unit       | Status     | LCR       | LNC       | UNC       | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
SYSTEM:
System_FW_Status | na         | discrete   | na         | na        | na        | na        | na
System_Watchdog  | 0x0        | discrete   |            | na        | na        | na        | na
Wrench_Port_Up   | na         | discrete   | na         | na        | na        | na        | na
CONTROLLER_A:
PCM_Status       | 0x0        | discrete   | Fault      | na        | na        | na        | na
Attn_Sensor1     | 0x0        | discrete   | Asserted   | na        | na        | na        | na
CPU-1_DTS_Temp   | na         | degrees C  | na         | na        | na        | -10.000   | 0.000
CPU-2_DTS_Temp   | na         | degrees C  | na         | na        | na        | -10.000   | 0.000
CPU0_PVCCP       | na         | Volts      | na         | 1.580     | 1.670     | 1.920     | 2.010
CPU1_PVCCP       | na         | Volts      | na         | 1.580     | 1.670     | 1.920     | 2.010

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.