Issue

  • HDD become unresponsive
  • Finally missing from RaidGroup
  • Replaced new HDD on the same shelf bay still have no signal(Both the amber LED and green LED are off)
  • The same HDD become operational after inserting it to different shelf bay.

[?] Mon Jan 16 01:50:01 KST [node02: pmcsas_timeout_0:sas.adapter.debug:info]: params: {'debug_string': 'Device 0d.10.3invalidated.', 'adapterName': '0a'}
[?] Mon Jan 16 01:50:01 KST [node02: pmcsas_timeout_0:sas.adapter.debug:info]: params: {'debug_string': 'Invalidating device 0d.10.3.', 'adapterName': '0a'}
[?] Mon Jan 16 01:50:01 KST [node02:scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device0d.10.3: Adapter/target error: HA status 0x7: cdb0x88:0000000122284080:00000240. Targeted device did not respond to requestedI/O. I/O will be retried.
[?] Mon Jan 16 01:50:01 KST [node02:scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device ?:?.?:Adapter/target error: HA status 0x7: cdb 0x28:5020e600:0240. Targeted devicedid not respond to requested I/O. I/O will be retried.
[?] Mon Jan 16 01:50:01 KST [node02: sanown_io:diskown.errorDuringIO:error]: error 25 (no valid path to disk) on disk 0b.10.3(S/N xxxxxxxx) while setting disk reservation
[?] Mon Jan 16 01:50:01 KST [node02: disk_server_0:disk.IO.status:debug]: params: {'deviceName': '0d.10.3', 'returnCode': '2','pathRetryCount': '0', 'adapterStatus': '0xd', 'cdb':'0x88:0000000122284080:00000240', 'basicTimeout': '10', 'iASCQ': '0x0','iSenseKey': '0x0', 'sSenseCode': '', 'ETime': '10568', 'iASC': '0x0','victimRetryCount': '10', 'sSenseKey': 'SCSI:no sense', 'targetStatus': '0x0','disk_information': 'Disk 0d.10.3 Shelf 10 Bay 3 [NETAPP   X308_HMRKP03TSSM NA00] S/N [xxxxxxxx] UID[500605BA:011BCC0C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]','retryCount': '1', 'pathsTried': '0', 'timeoutRetryCount': '0'}
[?] Mon Jan 16 01:50:01 KST [node02: config_thread:raid.config.filesystem.disk.missing:info]: File system Disk/aggr2/plex0/rg0/0d.10.3 Shelf 10 Bay 3 [NETAPP   X308_HMRKP03TSSM NA00] S/N [xxxxxxxx] UID[500605BA:011BCC0C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]is missing.
[?] Mon Jan 16 01:50:01 KST [node02: config_thread:raid.rg.degraded:notice]: : Raid group /aggr2/plex0/rg0 is degraded
[?] Mon Jan 16 01:50:02 KST [node02: config_thread:raid.rg.recons.missing:notice]: RAID group /aggr2/plex0/rg0 is missing 1disk(s).
[?] Mon Jan 16 01:50:02 KST [node02: config_thread:raid.rg.recons.info:notice]: Spare disk 0b.11.5 will be used to reconstruct onemissing disk in RAID group /aggr2/plex0/rg0.
[?] Mon Jan 16 01:50:02 KST [node02: config_thread:raid.rg.recons.start:notice]: /aggr2/plex0/rg0: starting reconstruction, usingdisk 0b.11.5, disk block 5248

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.