DS460 shelf fault reported for an open drawer
Applies to
- Ontap 9
- DS460
Issue
- Storage show fault shows that the shelf status is critical
::> node run -node <NodeName> storage show fault Enclosure Status: critical Channel: 1b Shelf: 54
- In same output one of the drawers show open
Drawers Control Module:
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : OK 01,00,01,00 REPORT
2 [IOM12 A] : OK 01,00,01,00 REPORT
3 [IOM12 A] : OK 01,00,01,00 REPORT
4: NOT INSTALLED 05,40,00,00
5 [IOM12 A] : OK 01,00,01,00 REPORT
6 [IOM12 B] : OK 01,00,01,00 REPORT
7 [IOM12 B] : OK 01,00,01,00 REPORT
8 [IOM12 B] : OK 01,00,01,00 REPORT
9 [IOM12 B] : OK 01,00,01,00 REPORT
10 [IOM12 B] : OK 01,00,01,00 REPORT - There may be other alerts for drives or IOMs
- This leads to disk redundancy alerts to be called out in auto supports
HA Group Notification (DISK REDUNDANCY FAILED) ERROR