DISK REDUNDANCY FAILED error due to IOM module
Applies to
- ONTAP 9
- IOM12B
Issue
- AutoSupport trigger subject
HA Group Notification (DISK REDUNDANCY FAILED) ERROR
. SYSCONFIG-A
shows less shelves over 1 path:
Path using IOM B:
Shelf 0: DS212-12 Firmware rev. IOM12E A: 0250 IOM12E B: 0250
Shelf 1: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 2: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 3: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 4: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 5: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Path using IOM A:
Shelf 1: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
SAS-EXPANDER-PHY-STATE
show rate as unknown.
Shelf name: Partner.shelf1
Shelf id: 1
Channel: Partner
Module: A
Shelf state: ONLINE
Module state: OK
Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------------
[HST8/P2:0 ] UNKWN LNK 0 NA 0 0 0 0 0 2
[HST9/P2:1 ] UNKWN LNK 0 NA 0 0 0 0 0 2
[HST10/P2:2] UNKWN LNK 0 NA 0 0 0 0 0 2
[HST11/P2:3] UNKWN LNK 0 NA 0 0 0 0 0 2
Shelf name: 0b.shelf3
Shelf id: 3
Channel: 0b
Module: A
Shelf state: ONLINE
Module state: OK
Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------------
[HST0/P0:0 ] UNKWN LNK 0 NA 0 0 0 0 0 2
[HST1/P0:1 ] UNKWN LNK 0 NA 0 0 0 0 0 2
[HST2/P0:2 ] UNKWN LNK 0 NA 0 0 0 0 0 2
[HST3/P0:3 ] UNKWN LNK 0 NA 0 0 0 0 0 2