DISK REDUNDANCY FAILED due to faulty shelf chassis
Applies to
- ONTAP 9
- DS460C shelf
Issue
The system reported a “DISK REDUNDANCY FAILED” event, associated with mixed-path errors on one drawer in an expanded shelf.
ERROR callhome.dsk.redun.fault: Call home for DISK REDUNDANCY FAILED
- Disks in a drawer are visible only through one IOM , not both.
slot 0: SAS Host Adapter 0b (Broadcom SAS3616W rev. 2, SAS, <UP>)
20.0 : NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.1 : NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.2 : NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.3 : NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.6 : NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.9 : NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.10: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.12: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.13: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect slot 0: SAS Host Adapter 0c (Broadcom SAS3616W rev. 2, SAS, <UP>) 20.12: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect20.13: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect- Replacing the IOM module or drawer did not resolve the issue.
