Applies to

  • AFF C800
  • ONTAP 9.14.1P11
  • Baseboard Management Controller (BMC)
  • BMC Firmware 10.9P1

Issue

  • Chassis attention LED is amber.
  • system controller service-event show command returns timeout errors.

::*> system controller service-event show
Warning: Unable to list entries on node node1. The Service Processor on node "node1" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.
Unable to list entries on node node2. Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.56.78]
Unable to list entries on node node3. Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.123.134]
Unable to list entries on node node4. Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.12.123]
Error: show failed: Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.12.123]

  • BMC SP-LATEST-IPMI shows an error for the P1V05_PCH_STBY sensor.

======================================
hsamcmd --fault-show-all
===============================
tag  origin  fld                                     fault reason                                    count  time                       
---- ------- ----                                    -------------                                   ------ -----                      
1    bmc     /chassis-1/controller-b                 P1V05_PCH_STBY: Voltage Sensor 16 LNC           1      Sat Mar  1 22:16:24 2025

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.