Chassis Amber LED is On and system controller service-event show Displays "Warning: Unable to list entries on node"
Applies to
- AFF C800
- ONTAP 9.14.1P11
- Baseboard Management Controller (BMC)
- BMC Firmware 10.9P1
Issue
- Chassis attention LED is amber.
system controller service-event show
command returns timeout errors.
::*> system controller service-event show
Warning: Unable to list entries on node node1. The Service Processor on node "node1" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.
Unable to list entries on node node2. Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.56.78]
Unable to list entries on node node3. Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.123.134]
Unable to list entries on node node4. Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.12.123]
Error: show failed: Timeout: Operation "service_event_iterator::next_imp()" took longer than 25 seconds to complete [from mgwd on node "node1" (VSID: -1) to mgwd at 169.234.12.123]
- BMC
SP-LATEST-IPMI
shows an error for theP1V05_PCH_STBY
sensor.
======================================
hsamcmd --fault-show-all
===============================
tag origin fld fault reason count time
---- ------- ---- ------------- ------ -----
1 bmc /chassis-1/controller-b P1V05_PCH_STBY: Voltage Sensor 16 LNC 1 Sat Mar 1 22:16:24 2025