Call home for DISK REDUNDANCY FAILED after disk replacement
Applies to
- Single disk bay
- DS4246
Issue
- AutoSupport "Call home" messages for failed disk redundancy. Example:
[node_name-01: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
[node_name-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
- Single disk reporting:
Enclosure Status: non-critical
Channel: 0a
Shelf: 1
Shelf Type: DS4246
Product Serial Number: SHJHU0123456789
Disk Elements:
Element Status Status Bytes Status Descriptions
5 [Bay 5]: NONCRITICAL 03,05,20,28 ENCLOSURE BYPASSED A, BYPASSED A, FAULT REQSTD
- Disk detected through the other SAS path:
slot 3: SAS Host Adapter 0b (Broadcom SAS3616W rev. 2, SAS, <UP>)
30.5 : NETAPP X477_WVRDX04TA07 NA02 3807.8GB 520B/sect (ABC1D2E34F56)
- Issue remains after disk replacement and/or swapped with a spare.