Skip to main content
NetApp Knowledge Base

BMC 16.8 upgrade may result in PSU3 and PSU4 faults

Views:
9
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • AFF A900/FAS9500
  • ONTAP 9
  • BMC firmware 16.8

Issue

  • After upgrading an AFF A900 or FAS9500 to BMC firmware 16.8, some systems may report a failure of PSU3 and PSU4
    • Example
          EMS log:
      Wed Apr 15 14:24:25 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 AC In Volt is Unreadable
      Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 AC In Curr is Unreadable
      Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 12V Out Volt is Unreadable
      Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 12V Out Curr is Unreadable
      Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 AC In Volt is Unreadable
      Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 AC In Curr is Unreadable
      Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 12V Out Volt is Unreadable
      Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 12V Out Curr is Unreadable

      SP-Latest-IPMI section in Autosupport (Specific affected sensors below. Output is the same for partner PSU4)

      PSU3_Status      | 0x0          | discrete   | AC OK      | na        | na        | na        | na        
      PSU3_12V_OP_I    |  na          | Amps       | na         | 0.000     | 0.000     | 140.000   | 144.000   
      PSU3_12V_OP_V    |  na          | Volts      | na         | 10.980    | 11.400    | 12.900    | 13.500    
      PSU3_AC_IP_I     |  na          | Amps       | na         | na        | na        | 14.000    | 14.980    
      PSU3_AC_IP_V     |  na          | Volts      | na         | 88.000    | 90.000    | 255.000   | 255.000   
      PSU3_Fault       |  na          | discrete   | na         | na        | na        | na        | na   

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.