AutoSupport Message: DISK/SHELF COUNT MISMATCH
Applies to
- ONTAP 9
- Data ONTAP 7 and earlier
Issue
- CLERDK:Cluster Notification from Filer1 (
CLUSTER ERROR: DISK/SHELF COUNT MISMATCH) ERROR
Message cfdisk: previous mismatch resolved
Error message: cfdisk: shelf count mismatch detected: local 3, partner 4
The followig AutoSupport messages sent might also be seen:
SHELF_FAULT
Filesystem Disk Fail
- With a disk show –n, the disk is not seen on the owning node.
disk show: No disks match option -n.
- Also, the disk is seen unassigned on the partner node.
DISK OWNER POOL SERIAL NUMBER
------------ ------------ ------ -------------
2c.16.23 Not Owned NONE JVVBHTHL
Note: When adding new disks to a storage system, the disks are assigned to the partner node. - Disk assignment fails with the following error:
disk assign: Disk 1a.16.23 not accessible. Error 19 (disk not ready for requested operation)