Attention LED stays ON on AFF-A400
Applies to
- AFF-A400
- FAS8300
Issue
- BMC auto-upgrade run into a race condition with the sensor policy.
- EMS shows:
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ ABC in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ DEF in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ GHI in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ KLM in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor P1V05 PCH in the controller module is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Inlet) is not readable.
[env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable. System will be shutdown in 10 minutes
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Outlet) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (MP Temp1) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (MP Temp3) is not readable.
[env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
[env_mgr: monitor.chassisTemperature.ok:notice]: Chassis temperature is ok.
[env_mgr: monitor.chassisPower.ok:notice]: Chassis power is OK.
system fru led show all
showsLED_SYSTEM_ATTEN_01 is on
:
0 LED_SYSTEM_LOCATION_01 is off
1 LED_SYSTEM_ATTEN_01 is on
2 LED_CONTROLLER_ATTEN_01 is off