AFF A400, A800, FAS8300, FAS8700: BIOS MRC mapped out DIMM messages
Applies to
- AFF-A400, AFF-C400, ASA-A400, ASA-C400
- AFF-A800, AFF-C800, ASA-A800, ASA-C800
- FAS8300
- FAS8700
Description
- On these systems, the BIOS might map out memory DIMMs when errors are encountered, such as:
DIMM: B0 mapped out. BIOS MRC mapped out DIMM. Major Code 0x30 Minor Code 0x13
- The BIOS message uses a two-letter code (
DIMM: B0
) to identify the DIMM with the error. - Example of PANIC message which would cause the DIMM mapped-out situation:
PANIC: ECC error at DIMM-13: CE-04-1944-427DADF8,ADDR 0x15e4014780,(Node(1), Memory controller(0), CH(1), DIMM(0), Rank(0), Bank Group(0), Bank(0x0), Row(0x15c80), Col(0x318)) Uncorrectable Machine Check Error at CPU13. ...
...
System rebooting...
...
Running full memory initialization.
DIMM F0: NVDIMM pending and destage progressing.....
PPR:Hard
PPR:Processing 0x1/0x0/0x1/0x0/0x0/0x0/0x0/0x0/0x15C80
PPR:Pre-PPR Row test PASS. dramMask = 0x0
PPR:Post-PPR Row test PASS. dramMask = 0x0
PPR:Sequence PASS
DIMM F0: NVDIMM with valid data and restage progressing.....
MEMORY WARNING: Major Code 0x30 Minor Code 0x2d DIMM:H0
DIMM:H0 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0a Minor Code 0x03
DIMM:H0 mapped out. BIOS MRC mapped out DIMM. Major Code 0x0b Minor Code 0x1c
...
System DIMM configuration is not supported by AFF-A400
Halting...
...
LOADER-A>